Automatic titration and calculation by predictive equations for the determination of therapeutic continuous positive airway pressure for obstructive sleep apnea
Authors:Marrone Oreste  Salvaggio Adriana  Romano Salvatore  Insalaco Giuseppe
Institution:Italian National Research Council, Institute of Biomedicine and Molecular Immunology, A. Monroy, Sleep Laboratory, Palermo, Italy. marrone@ibim.cnr.it
Abstract:BACKGROUND: It is unknown to what extent therapeutic continuous positive airway pressure (CPAP) levels obtained by various methods for the treatment of obstructive sleep apnea syndrome (OSAS) differ. This study aimed to explore the relationships among pressures titrated by an automatic CPAP (APAP) device and those calculated using different predictive equations, and to compare different ranges of calculated pressures with pressure values titrated by APAP. METHODS: In 140 OSAS patients, the 95th percentile pressure delivered by an APAP device (AutoSet T; ResMed; Sydney, NSW, Australia) during polysomnography, and pressures calculated by three equations (equation 1, Hoffstein and Miljetig 1994]; equation 2, Sériès et al 2000]; and equation 3, Stradling et al 2004]) were compared. RESULTS: Titrated and calculated pressures were weakly correlated. Significant differences were found between the mean (+/- SD) pressures (11.1 +/- 1.6, 8.3 +/- 1.8, 10.5 +/- 1.6, and 10.3 +/- 1.3 cm H(2)O, respectively) for 95th percentile APAP, and pressures calculated by equations 1, 2, and 3, except between values calculated by equations 2and 3. Differences between the calculated and APAP-derived pressures were negative for the low calculated values, and were progressively attenuated, or became positive, for the high values. The differences were smallest for calculated pressures from 11 to > 13 cm H(2)O, which were represented to a greater extent among the values calculated by equations 2 and 3 than by those calculated by equation 1. CONCLUSIONS: Considerably different therapeutic CPAP levels may be determined using various methods. The differences between the calculated and APAP-derived pressures are largest for calculated values of < 9 or > 15 cm H(2)O. The clinical consequences of these findings deserve further evaluation. Caution is still required before treating OSAS patients with calculated pressures.
Keywords:hypoxemia  positive-pressure breathing  sleep apnea  AHI"}  {"#name":"keyword"  "$":{"id":"cekeyw440"}  "$$":[{"#name":"text"  "_":"apnea-hypopnea index  APAP"}  {"#name":"keyword"  "$":{"id":"cekeyw450"}  "$$":[{"#name":"text"  "_":"auto-continuous positive airway pressure  BMI"}  {"#name":"keyword"  "$":{"id":"cekeyw470"}  "$$":[{"#name":"text"  "_":"body mass index  CPAP"}  {"#name":"keyword"  "$":{"id":"cekeyw480"}  "$$":[{"#name":"text"  "_":"continuous positive airway pressure  NC"}  {"#name":"keyword"  "$":{"id":"cekeyw490"}  "$$":[{"#name":"text"  "_":"neck circumference  oAHI"}  {"#name":"keyword"  "$":{"id":"cekeyw500"}  "$$":[{"#name":"text"  "_":"obstructive apnea-hypopnea index  ODI"}  {"#name":"keyword"  "$":{"id":"cekeyw510"}  "$$":[{"#name":"text"  "_":"oxygen desaturation index  OSAS"}  {"#name":"keyword"  "$":{"id":"cekeyw520"}  "$$":[{"#name":"text"  "_":"obstructive sleep apnea syndrome  REM"}  {"#name":"keyword"  "$":{"id":"cekeyw530"}  "$$":[{"#name":"text"  "_":"rapid eye movement  TST"}  {"#name":"keyword"  "$":{"id":"cekeyw540"}  "$$":[{"#name":"text"  "_":"total sleep time
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号