首页 | 本学科首页   官方微博 | 高级检索  
     


Open surgical repair for a perigraft leak after endovascular stent-graft emplacement of descending thoracic aneurysm
Authors:Atsushi Iguchi   Yusuke Tsuru   Hitoshi Yokoyama  Koichi Tabayashi
Affiliation:Department of Cardiovascular Surgery, Graduate School of Medicine, Tohoku University, 1-1 Seiryomachi, Aoba-ku, Sendai, 980-8574, Japan.
Abstract:Although transluminal stent-graft implantation is less invasive for treating an aneurysm in the thoracic descending aorta, this technique is not always successful. Here, we report two cases of a perigraft leak identified after stent-graft deployment, and complete occlusion of the leak could not be attained by additional stent-graft deployment. Open surgical repair using a stented graft was performed through a median sternotomy without opening the left pleura. This procedure should be considered as one of the less-invasive techniques for treating a perigraft leak after endovascular stent-graft emplacement.
Keywords:
本文献已被 SpringerLink 等数据库收录!