首页 | 本学科首页   官方微博 | 高级检索  
     

利用散斑追踪原理检测高强度聚焦超声所致凝固性坏死
引用本文:钟珊珊,向军,李雁,冯玉洁,王华. 利用散斑追踪原理检测高强度聚焦超声所致凝固性坏死[J]. 中国医学影像技术, 2010, 26(5): 967-970
作者姓名:钟珊珊  向军  李雁  冯玉洁  王华
作者单位:重庆医科大学生物医学工程系,超声医学工程重庆市市级重点实验室,重庆,400016
摘    要:目的 探讨利用散斑追踪法检测凝固性坏死发生的可行性.方法 利用散斑追踪原理选择相关系数作为评估参数,对比治疗前后靶区声像图的相似程度,并检测凝固性坏死的情况.结果 共进行辐射180个点,利用灰度处理软件判断组织发生凝固性坏死的正确率为65.60%,错误率为34.40%.以90 W为例,辐照后有凝固性坏死发生且有明显灰度变化时,相关系数绝对值小于0.58,辐照后有凝固性坏死发生且无明显灰度变化时,相关系数绝对值小于0.75.结论 散斑追踪法较利用强回声判断凝固性坏死的方法更敏感,且当图像采集条件保持一致时有很高的稳定性,可能会成为检测凝固性坏死的一种新手段.

关 键 词:高强度聚焦超声  散斑追踪  相关系数
收稿时间:2009-11-26
修稿时间:2009-12-18

Tracing and detection coagulation necrosis induced by high intensity focused ultrasound under speckle technique
ZHONG Shan-shan,XIANG Jun,LI Yan,FENG Yu-jie and WANG Hua. Tracing and detection coagulation necrosis induced by high intensity focused ultrasound under speckle technique[J]. Chinese Journal of Medical Imaging Technology, 2010, 26(5): 967-970
Authors:ZHONG Shan-shan  XIANG Jun  LI Yan  FENG Yu-jie  WANG Hua
Affiliation:1.Department of Biomedical Engineering, Chongqing Medical University,Chongqing Key Laboratory of Ultrasound Medical Engineering, Chongqing 400016, China;1.Department of Biomedical Engineering, Chongqing Medical University,Chongqing Key Laboratory of Ultrasound Medical Engineering, Chongqing 400016, China;1.Department of Biomedical Engineering, Chongqing Medical University,Chongqing Key Laboratory of Ultrasound Medical Engineering, Chongqing 400016, China;1.Department of Biomedical Engineering, Chongqing Medical University,Chongqing Key Laboratory of Ultrasound Medical Engineering, Chongqing 400016, China;1.Department of Biomedical Engineering, Chongqing Medical University,Chongqing Key Laboratory of Ultrasound Medical Engineering, Chongqing 400016, China
Abstract:Objective To study the feasibility of utilization of speckle tracing principles to detect the incidence of coagulation necrosis caused by high intensity focused ultrasound (HIFU). Methods In order to detect the incidence of coagulation necrosis, the correlation coefficients were selected as evaluation parameters to compare the similarity of target ultrasound image before and after HIFU radiation with the speckle tracing principles, and histogenesis of coagulation necrosis was detected. Results There were 180 points of radiation, and the correct rate and error rate was 65.60% and 34.40% respectively with gray-processing software to determine histogenesis of coagulation necrosis. Taking the radiation power of 90 W for example, when the correlation coefficients was lower than 0.58, there was both incidence of coagulation necrosis and obvious gray variation; when the correlation coefficients was less than 0.75, there was no gray variation but coagulation necrosis occurred. Conclusion Speckle tracing is more sensitive than strong echoes way in the judgment of the coagulation necrosis, and the stability is very good when the image acquisition conditions keep consistent. Speckle tracing can become a new way to detect the incidence of coagulation necrosis.
Keywords:High intensity focused ultrasound  Speckle tracing  Correlation coefficient
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载全文