首页 | 本学科首页   官方微博 | 高级检索  
检索        

CT灌注成像对超急性脑梗死半暗带两种判定方法的一致性研究
引用本文:陈唯唯,漆剑频,肖明,宋金梅.CT灌注成像对超急性脑梗死半暗带两种判定方法的一致性研究[J].中国医学影像技术,2005,21(2):258-260.
作者姓名:陈唯唯  漆剑频  肖明  宋金梅
作者单位:华中科技大学同济医学院附属同济医院放射科,湖北,武汉,430030
摘    要:目的探讨CT灌注成像缺血半暗带两种判定方法的一致性.方法采用GELightSpeed 16 MSCT对10例超急性脑缺血患者进行CT灌注成像和复查CT.采用两种方法判定半暗带,一种是计算半暗带阈值以判定半暗带(对比法),另一种是将CBV与CBF图上变化不一致的区域判断为半暗带(不匹配法).结果半暗带阈值(CBF%)为0.20~0.66,两种方法间一致性系数Kappa(K)为0.7877.ROC曲线显示对比法的诊断效能高于不匹配法.结论 CT灌注成像判定半暗带的两种方法具有较好的一致性.

关 键 词:超急性脑梗死  体层摄影术  X线计算机  灌注  半暗带
文章编号:1003-3289(2005)02-0258-03
收稿时间:2004/12/12 0:00:00
修稿时间:2004年12月12

Consistency between two methods for penumbra assessment by CT perfusion in hyperacute cerebral ischemia
CHEN Wei-wei,QI Jian-pin,XIAO Ming and SONG Jin-mei.Consistency between two methods for penumbra assessment by CT perfusion in hyperacute cerebral ischemia[J].Chinese Journal of Medical Imaging Technology,2005,21(2):258-260.
Authors:CHEN Wei-wei  QI Jian-pin  XIAO Ming and SONG Jin-mei
Institution:Department of Radiology, Tongji Hospital, Tongji Medical College,Huazhong University of Science and Technology, Wuhan 430030, China;Department of Radiology, Tongji Hospital, Tongji Medical College,Huazhong University of Science and Technology, Wuhan 430030, China;Department of Radiology, Tongji Hospital, Tongji Medical College,Huazhong University of Science and Technology, Wuhan 430030, China;Department of Radiology, Tongji Hospital, Tongji Medical College,Huazhong University of Science and Technology, Wuhan 430030, China
Abstract:Objective To evaluate the consistency between two reported methods for assessing the penumbra in hyperacute cerebral ischemia by CT perfusion. Methods Ten hyperacute cerebral ischemic patients were performed CT perfusion and follow up scans after a week with a GE Lightspeed 16 MSCT. The penumbra was determined by two methods. The penumbra was determined by threshold value which were calculated by comparison the follow up scan with CTP results in the contrast method. Another was the mismatch of the CBV and CBF (the mismatch method). Results The threshold value of the penumbra (CBF%) was 0.20-0.66. The consistency coefficient Kappa (K) of the two methods was 0.7877. ROC curve showed that the contrast method had higher diagnostic efficacy than the mismatch method. Conclusion A high consistency was found between the two methods for identifying the penumbra.
Keywords:Hyperacute cerebral ischemia  Tomography  X-ray computed  Perfusion  Penumbra
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号