首页 | 本学科首页   官方微博 | 高级检索  
     

晶状体密度与超声乳化动力学参数的量化关系
引用本文:李乃洋,赵岐,冷炫,李中庭,陈毅华,李晟. 晶状体密度与超声乳化动力学参数的量化关系[J]. 眼科新进展, 2018, 0(2): 136-138. DOI: 10.13389/j.cnki.rao.2018.0029
作者姓名:李乃洋  赵岐  冷炫  李中庭  陈毅华  李晟
作者单位:528403 广东省中山市,中山市人民医院眼科中心
摘    要:目的 探讨晶状体密度计(opacity lensmeter,OLM)和Pentacam所测量的晶状体密度与超声乳化动力学各参数之间的量化关系。方法 收集年龄相关性核性白内障患者78例(78眼)。术前分别用OLM、Pentacam测量晶状体密度,并记录超声乳化白内障吸出术中的超声乳化动力学参数:超声时间(ultrasound time,UST)、累积超声能量(cumulated dissipated energy,CDE)和平衡盐溶液(balanced salt solution,BSS)使用量。分析晶状体密度与各个超声乳化动力学参数之间的相关关系。结果 OLM测量的晶状体密度为32.83±14.41,Pentacam测量的晶状体密度为15.26±5.82。术中UST为(50.65±22.58)s,CDE为12.96±6.22,BSS为(71.77±17.19)mL。OLM和Pentacam测量的晶状体密度与UST均呈正相关关系(r=0.645、0.807;均为P<0.05),与CDE亦均呈正相关关系(r=0.669、0.828;均为P<0.05)。与OLM相比,Pentacam与UST、CDE的相关性更高(Z=2.153、2.283;均为P<0.05)。结论 OLM和Pentacam测量的晶状体密度与UST和CDE均呈正相关,Pentacam比OLM的相关性更高。

关 键 词:白内障  晶状体密度  超声乳化动力学

Correlation of lens density and phacodynamics parameters in phacoemulsification
LI Nai-Yang,ZHAO Qi,LENG Xuan,LI Zhong-Ting,CHEN Yi-Hua,LI Sheng. Correlation of lens density and phacodynamics parameters in phacoemulsification[J]. Recent Advances in Ophthalmology, 2018, 0(2): 136-138. DOI: 10.13389/j.cnki.rao.2018.0029
Authors:LI Nai-Yang  ZHAO Qi  LENG Xuan  LI Zhong-Ting  CHEN Yi-Hua  LI Sheng
Affiliation:Eye Centre,Zhongshan City People’s Hospital,Zhongshan 528403,Guangdong Province,China
Abstract:Objective To evaluate the correlation of lens density (LD) measured by opacity lensmeter (OLM) and Pentacam with phacodynamics in patients with age-related nuclear cataract.Methods A prospective study was conducted in 78 patients (78 eyes) with age-related nuclear cataract.The lens density was measured with OLM and Pentacam respectively before operation,and the phacoemulsification kinetic parameters in phacoemulsification,including ultrasound time (UST),cumulated dissipated energy (CDE) and balanced salt solution (BSS) usage,were recorded for the analysis of the correlations of LD values with phacodynamics.Results LD measured by OLM and Pentacam was 32.83±14.41 and 15.26±5.82,respectively.LD from OLM and Pentacam was positively correlated with both UST (r=0.645,0.807,respectively;both P<0.05) and CDE (r=0.669,0.828,respectively;both P<0.05).UST and CDE were more strongly correlated with LD from Pentacam than from OLM (Z=2.153,2.283;both P<0.05).Conclusion LD from both OLM and Pentacam are correlated with UST and CDE,and a stronger correlation is observed in Pentacam than OLM.
Keywords:cataract   lens density   phacodynamics
点击此处可从《眼科新进展》浏览原始摘要信息
点击此处可从《眼科新进展》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号