首页 | 本学科首页   官方微博 | 高级检索  
检索        


Hearing rehabilitation with osseointegrated hearing implant in bilateral congenital external auditory canal atresia
Institution:Department of Otolaryngology and Head and Neck Surgery, Centro Hospitalar Universitário do Porto, Portugal
Abstract:Introduction and objectivesCongenital atresia of the external auditory canal (EAC) is a congenital defect present in one in every 10,000–20,000 births. It causes conductive hearing loss, with an air-bone gap of 50–60 dB. Early amplification is essential in bilateral cases to ensure normal language development. The aim of this study is to present the osseointegrated hearing implant as a treatment for bilateral EAC atresia, reviewing the audiometric results and the rate of complications.Material and methodsRetrospective analysis of patients diagnosed with bilateral congenital EAC atresia under follow-up in the pediatric ENT clinic of the ENT and Head and Neck Surgery department of a Portuguese Tertiary Hospital, between 2003 and 2019. We reviewed the medical records and collected information on the assessment of the initial audiometric status. In the cases submitted for implantation with an osseointegrated hearing implant, we analyzed the details of follow-up, including immediate and long-term post-operative complications, as well as the audiometric results.ResultsWe present 8 pediatric patients, 6 girls and 2 boys, with a diagnosis of bilateral congenital EAC atresia. The audiometric assessment revealed moderate to severe bilateral conductive hearing loss with a mean speech recognition threshold (SRT) of 51 dB. Six patients underwent osseointegrated hearing implantation. All 6 patients showed good audiometric results, with an average SRT of 20 dB and closure of the air-bone gap.ConclusionsThe osseointegrated hearing implant was an effective treatment option in these patients, without significant morbidity or complications. Osseointegrated hearing implantation should be considered first line treatment for children with bilateral congenital EAC atresia, as it presents good functional results and a high level of patient satisfaction.
Keywords:Congenital atresia of the external auditory canal  Hearing implant  Bone conduction  Hearing loss  Children  Atresia congénita del canal auditivo externo  Implante auditivo osteointegrado  Conducción ósea  Hipoacusia  Niños  EAC"}  {"#name":"keyword"  "$":{"id":"kw0060"}  "$$":[{"#name":"text"  "_":"external auditory canal  BAHA"}  {"#name":"keyword"  "$":{"id":"kw0070"}  "$$":[{"#name":"text"  "_":"bone anchored hearing aids  CT"}  {"#name":"keyword"  "$":{"id":"kw0080"}  "$$":[{"#name":"text"  "_":"computerized tomography  SRT"}  {"#name":"keyword"  "$":{"id":"kw0090"}  "$$":[{"#name":"text"  "_":"speech recognition threshold
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号