首页 | 本学科首页   官方微博 | 高级检索  
     


Hinge plate technique for osteosynthesis of comminuted proximal humeral fractures
Affiliation:1. University of Fribourg Medical School, Switzerland;2. Department of Orthopaedics and Traumatology, Fribourg Cantonal Hospital, Switzerland;3. Lugano Regional Hospital, Switzerland;4. Service of Plastic and Hand Surgery, Lausanne University Hospital, Switzerland;1. Cambridge Orthopaedic Pelvic Unit (COPU), Addenbrooke''s Hospital Major Trauma Centre, Cambridge University Hospitals NHS Foundation Trust, United Kingdom;2. Division of Trauma and Orthopaedic Surgery, University of Cambridge, United Kingdom;1. Queens Medical Centre, Nottingham, NG7 2UH, United Kingdom;2. Academic Orthopaedics, Trauma & Sports Medicine, University of Nottingham, Nottingham, NG7 2RD, United Kingdom;1. R Adams Cowley Shock Trauma Center Division of Orthopaedic Traumatology 22 S Greene St, Baltimore, MD 21201, United States;2. University of San Diego Department of Mathematics, 5998 Alcala Park, San Diego, CA 92110, United States;1. Department of Surgical Gastroenterology, Rigshospitalet, University of Copenhagen, Denmark;2. Center for Surgical Translational and Artificial Intelligence Research (CSTAR), Rigshospitalet, University of Copenhagen, Denmark.;3. Department of Anesthesia, Center of Head and Orthopedics, Rigshospitalet, University of Copenhagen, Denmark;4. Proteomics Core, Technical University of Denmark, Lyngby, Denmark.;5. Department of Clinical Medicine, University of Copenhagen, Denmark;1. Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital, University Hospital of Southern Denmark, Sygehusvej 24, 6000 Kolding, DK;2. Department of Orthopaedic Surgery and Traumatology, Bispebjerg Hospital, DK
Abstract:BackgroundSeveral surgical techniques of osteosynthesis have been described for treatment of proximal humeral fractures. There is evidence that the quality of reduction improves the clinical outcome and decreases the number of complications. Reduction of the medial calcar is tricky when standard manoeuvres are performed. We have therefore augmented our standard surgical technique with a low-profile medial hinge plate which aims at better reconstructing the medial metaphysis without extensile soft tissue dissection in combination with proximal humerus locked plating.ObjectiveEvaluate the radiological and clinical outcome after application of an augmented fixation with a low-profile medial hinge plate. We questioned: (i) The quality of reduction, (ii) The rate of complications, (iii) The clinical function in terms of the Oxford Shoulder Score (OSS).MethodsA retrospective single-centre case series. Between 2016 and 2019, patients who had undergone open reduction and osteosynthesis by an anatomical locking plate associated with a 2.0 mm locking compression plate used as a hinge to support the medial metaphysis. Thirty-four patients, with an average age of 64 years had a clinical and/or radiological average follow-up of 36 months.ResultsThe preoperative imaging identified three fractures in two parts, 19 fractures in three parts and 12 fractures in four parts. Seven cases with fracture-dislocation were identified, one head-split fracture, and 14 cases with a metaphyseal head extension of less than 8 mm. After comparing head-shaft displacement, cranialisation of the greater tuberosity as well as head-shaft alignment in the preoperative and postoperative radiographs, overall anatomical or near-anatomical fracture reduction was achieved in 27 of the patients.Only two cases presented postoperative complications. The two cases were complicated with nonunion without screw perforation requiring surgical intervention by re-osteosynthesis. The clinical outcome assessed by the OSS showed an average of 45/48.The age of the group with anatomical or near anatomical reduction and the group with at least one parameter of malreduction was significantly different, 65 and 74 years respectively (p<0.05). No significant differences were found when comparing the sex, surgical time, time to operation or the number of fracture parts.ConclusionThe technique described provides a surgical treatment option with lower complication rates and a quality of reduction consistent with the current literature as well as a satisfactory clinical outcome.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号