Estimation of Duloxetine Hydrochloride in Pharmaceutical Formulations by RP-HPLC Method |
| |
Authors: | Patel Sejal K Patel N J Patel K M Patel P U Patel B H |
| |
Affiliation: | S. K. Patel college of Pharmaceutical Education and Research, Ganpat University, Kherava-382 711, India |
| |
Abstract: | Simple, specific, accurate and precise method, namely, reverse phase high performance liquid chromatography was developed for estimation of duloxetine HCl in pharmaceutical formulations. For the high performance liquid chromatography method, Phenomenox C-18, 5 μm column consisting of 250×4.6 mm i.d. in isocratic mode, with mobile phase containing 0.01M 5.5 pH phosphate buffer: acetonitrile (60:40 v/v) and final pH adjust to 5.5±0.02 with phosphoric acid was used. The flow rate was 1.2 ml/min and effluent was monitored at 231 nm. The retention time was 5.61 min. The method was validated in terms of linearity, accuracy and precision. The linearity curve was found to be linear over 0.25-4 μg/ml. The limit of detection and limit of quantification were found to be 0.10 and 0.25 μg/ml respectively. The proposed method was successfully used to determine the drug content of marketed formulations. |
| |
Keywords: | Duloxetine HCl isocratic mode RP-HPLC SSNRI |
本文献已被 PubMed 等数据库收录! |
|