动态血糖监测在老年人无症状低血糖检测中的应用
引用本文:于春梅.动态血糖监测在老年人无症状低血糖检测中的应用[J].中国医疗器械信息,2022(4):149-151.
作者姓名:于春梅
作者单位:阜新市糖尿病医院
摘    要:目的:为提高老年人无症状低血糖诊断准确率,促使患者及时治疗,研究探讨动态血糖监测在老年人无症状低血糖检测中的应用.方法:采用回顾性分析法选取2015年3月~2018年3月本院收治的老年无症状低血糖患者100例为研究对象,采用随机数字表法将100例老年无症状低血糖患者分为对照组和观察组,其中对照组有患者50例,观察组有患...

关 键 词:动态血糖监测  老年人无症状低血糖检测  手动血糖监测

Application of Ambulatory Blood Glucose Monitoring in the Detection of Asymptomatic Hypoglycemia in the Elderly
YU Chun-mei.Application of Ambulatory Blood Glucose Monitoring in the Detection of Asymptomatic Hypoglycemia in the Elderly[J].China Medical Devices Information,2022(4):149-151.
Authors:YU Chun-mei
Institution:(Fuxin Diabetes Hospital,Liaoning Fuxin 123000)
Abstract:Objective:In order to improve the diagnostic accuracy of asymptomatic hypoglycemia in the elderly and promote the timely treatment of patients,the application of dynamic blood glucose monitoring in the detection of asymptomatic hypoglycemia in the elderly was studied.Methods:100 elderly patients with asymptomatic hypoglycemia treated in our hospital from March 2015 to March 2018 were selected as the research object by retrospective analysis.100 elderly patients with asymptomatic hypoglycemia were divided into control group and observation group by random number table method,including 50 patients in the control group and 50 patients in the observation group.The patients in the control group were detected by manual blood glucose monitoring method,The observation group used the dynamic blood glucose monitoring method to detect the patients,and then collected and analyzed the test results of the control group and the observation group,and compared the accuracy of blood glucose monitoring of the two groups with different methods.Results:In the observation group,there were 2 missed patients,accounting for 4.00%,and 48 confirmed patients,accounting for 96.00%.It can be seen that the accuracy of blood glucose monitoring in the observation group was 96.00%,and the missed diagnosis rate was 4.00%;In the control group,there were 7 missed patients,accounting for 14.00%,2 false patients,accounting for 4.00%,41 confirmed patients,accounting for 82.00%.In the control group,the accuracy of blood glucose monitoring was 82.00%,and the missed diagnosis rate was 4.00%.According to the comparative monitoring results,the accuracy of blood glucose monitoring in the observation group was significantly higher than that in the control group(P<0.05).The data comparison difference between the two groups was significant and statistically significant.At the same time,the missed measurement rate and false measurement rate of blood glucose monitoring in the observation group were significantly lower than that in the control group(P<0.05).The data comparison difference between the two groups was significant and statistically significant.Conclusion:The detection of asymptomatic blood glucose in the elderly by dynamic blood glucose monitoring can effectively improve the detection results.
Keywords:dynamic blood glucose monitoring  asymptomatic hypoglycemia detection in the elderly  manual blood glucose monitoring