摘    要:目的:分析闭角型青光眼患者行复合式小梁切除术后1mo内发生高眼压(>21mmHg)的原因及处理方法。

方法:回顾性研究我院2010-03/2013-03应用复合式小梁切除术治疗闭角型青光眼术后1mo内高眼压的病例34例38眼,分析其原因,总结处理方法。

结果:导致术后早期高眼压的因素有:恶性青光眼8例9眼,巩膜瓣下血凝块及结缔组织阻塞13例15眼,术后前房积血5例5眼,巩膜瓣内切口被虹膜组织嵌顿3例3眼,术前高眼压持续时间长4例5眼,原因不明1例1眼。经对症治疗后,患者眼压均控制在21mmHg以下。

结论:闭角型青光眼行复合式小梁切除术后早期高眼压是由多因素造成的,早期预防、及时处理是手术成功的关键。

关 键 词:闭角型青光眼    复合式小梁切除术    早期    高眼压
收稿时间:2014/5/19 0:00:00
修稿时间:2014/7/30 0:00:00

Causes analysis of early postoperative high intraocular pressure of angle-closure glaucoma underwent compound trabeculectomy
Ya-Nan Li,Yun-Dong Yang,Si-Tuo Liang,Wen-Zong Zhou and Shen Xu.Causes analysis of early postoperative high intraocular pressure of angle-closure glaucoma underwent compound trabeculectomy[J].International Journal of Ophthalmology,2014,14(9):1691-1693.
Authors:Ya-Nan Li  Yun-Dong Yang  Si-Tuo Liang  Wen-Zong Zhou and Shen Xu
Institution:Department of Glaucoma, Cangzhou Eye Hospital, Cangzhou 061000, Hebei Province, China;Department of Glaucoma, Cangzhou Eye Hospital, Cangzhou 061000, Hebei Province, China;Department of Glaucoma, Cangzhou Eye Hospital, Cangzhou 061000, Hebei Province, China;Department of Glaucoma, Cangzhou Eye Hospital, Cangzhou 061000, Hebei Province, China;Department of Glaucoma, Cangzhou Eye Hospital, Cangzhou 061000, Hebei Province, China
Abstract:AIM:To analyze the causes and treatments of high intraocular pressure(>21mmHg)of angle-closure glaucoma underwent compound trabeculectomy 1mo after surgery.

METHODS:This was a retrospective study of our hospital, from March 2010 to March 2013. Thirty-four(38 eyes)of angle-closure glaucoma patients were collected, who underwent compound trabeculectomy with high intraocular pressure(>21mmHg)1mo after operation. We analyzed the causes and summarized the treatments.

RESULTS:The causes which lead to early postoperative high intraocular pressure included malignant glaucoma(9 eyes of 8 cases), blood clot and connective tissue block under the scleral flap(15 eyes of 13 cases), hyphema after surgery(5 eyes of 5 cases), sclera flap incision was incarcerated with iris tissue(3 eyes of 3 cases), preoperative high intraocular pressure for a long time(5 eyes of 4 cases), 1 eye of 1 case for unknown reason. After proper treatments, intraocular pressures of all patients were bellowed 21mmHg.

CONCLUSION:Early postoperative high intraocular pressure of angle-closure glaucoma underwent compound trabeculectomy is caused by various factors, and the early prevention and timely treatment are key points of a successful operation.

Keywords:angle-closure glaucoma  compound trabeculectomy  early stage  high intraocular pressure