首页 | 本学科首页   官方微博 | 高级检索  
检索        

三种不同IOL植入术后短期的视力和视觉干扰现象及脱镜率的对比
引用本文:张岩,吴元奇,吴佳恒,张民军.三种不同IOL植入术后短期的视力和视觉干扰现象及脱镜率的对比[J].国际眼科杂志,2024,24(1):106-110.
作者姓名:张岩  吴元奇  吴佳恒  张民军
作者单位:中国浙江省嘉兴市,嘉兴爱尔眼科医院;中国浙江省湖州市,湖州爱尔眼科医院
基金项目:嘉兴市科技计划项目(No.2022AY30006)
摘    要:目的:对比分析单眼植入三焦点、多焦点及连续视程人工晶状体(IOL)术后短期的视力、视觉干扰现象及脱镜率。方法:回顾性分析2019-03/2022-12行超声乳化白内障吸除联合IOL植入术的白内障患者67例67眼。35例35眼植入Symfony连续视程IOL; 21例21眼植入AcrySof IQ ReSTOR+3D多焦点IOL; 11例11眼植入AcrySof IQ PanOptix三焦点IOL。记录术前及术后3 mo裸眼远视力(UDVA)、中视力(UIVA)、近视力(UNVA),术后3 mo离焦曲线、视觉干扰现象及脱镜率。结果:术后3 mo,三组间UDVA无差异(P>0.05); Symfony组及PanOptix组UIVA优于ReSTOR组(均P<0.01); ReSTOR组及PanOptix组UNVA优于Symfony组(均P<0.01)。离焦曲线显示,在中视力区间(-1.00--1.50 D),Symfony组视力优于ReSTOR组(P<0.05); 在近视力区间(-2.50--3.50 D),ReSTOR组视力优于Symfony组(P<0.05); PanOptix组在近视力区间(-2.00--3.50 D)的视力优于Symfony组(P<0.05),同时在中视力区间(-1.00--2.00 D)的视力优于ReSTOR组(P<0.05)。三组间眩光或光晕的发生率及双眼相互干扰现象发生率均无差异(P>0.05)。PanOptix组和ReSTOR组脱镜率比Symfony组高(P<0.0167)。结论:与Symfony连续视程IOL和ReSTOR多焦点IOL相比,PanOptix三焦点IOL能够兼顾远中近视力,眩光和光晕发生率不高,脱镜率较高; 单眼植入老视矫正型IOL仍需慎重。

关 键 词:人工晶状体(IOL)    连续视程    多焦点人工晶状体    三焦点人工晶状体    离焦曲线    视觉干扰    脱镜率
收稿时间:2023/7/26 0:00:00
修稿时间:2023/11/29 0:00:00

Comparison of short-term visual acuity and visual disturbance phenomena and spectacle independence after implantation of three different intraocular lenses
Zhang Yan,Wu Yuanqi,Wu Jiaheng,Zhang Minjun.Comparison of short-term visual acuity and visual disturbance phenomena and spectacle independence after implantation of three different intraocular lenses[J].International Journal of Ophthalmology,2024,24(1):106-110.
Authors:Zhang Yan  Wu Yuanqi  Wu Jiaheng  Zhang Minjun
Institution:Jiaxing Aier Eye Hospital, Jiaxing 314000, Zhejiang Province, China;Huzhou Aier Eye Hospital, Huzhou 313000, Zhejiang Province, China
Abstract:AIM: To compare the short-term postoperative visual acuity, visual disturbance phenomena, and spectacle independence rate in patients who underwent monocular implantation with trifocal, multifocal, or extended range of vision intraocular lens(IOL).METHODS: A retrospective analysis was conducted on 67 cataract patients(67 eyes)who underwent phacoemulsification cataract extraction combined with IOL implantation from March 2019 to December 2022. A total of 35 cases(35 eyes)received Symfony extended range of vision IOL implantation, 21 cases(21 eyes)received AcrySof IQ ReSTOR +3D multifocal IOL, and 11 cases(11 eyes)received AcrySof IQ PanOptix trifocal IOL. The preoperative uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA), and uncorrected near visual acuity(UNVA)and 3 mo postoperatively were documented. Moreover, defocus curves, visual disturbance phenomena, and spectacle independence rates were recorded at 3 mo postoperatively.RESULTS: At 3 mo postoperatively, no statistically significant differences were observed in UDVA among the three groups(P>0.05). A comparison of UIVA showed superior results in the Symfony and PanOptix groups compared to the ReSTOR group(all P<0.01). The UNVA of both the ReSTOR and PanOptix groups outperformed the Symfony group(all P<0.01). The defocus curves indicated that in the intermediate vision range(-1.00 to -1.50 D), the Symfony group exhibited better performance than the ReSTOR group(P<0.05); while in the near vision range(-2.50 to -3.50 D), the ReSTOR group was superior to the Symfony group(P<0.05). The PanOptix group demonstrated superior visual acuity in the near vision range(-2.00 to -3.50 D)compared to the Symfony group(P<0.05)and was also superior in the intermediate vision range(-1.00 to -2.00 D)compared to the ReSTOR group(P<0.05). No significant differences were observed in the incidence of glare or halo and binocular interference phenomena among the three groups(P>0.05). The PanOptix and ReSTOR groups exhibited a higher spectacle independence rate compared to the Symfony group(P<0.0167).CONCLUSION: Compared to Symfony extended range of vision IOL and ReSTOR multifocal IOL, PanOptix trifocal IOL offers a balanced approach to distance, intermediate, and near visual acuity, without a high incidence of glare and halo, and with a higher spectacle independence rate. Caution is still advised when considering monocular implantation with presbyopia-correcting IOLs.
Keywords:intraocular lens(IOL)  extended range of vision  multifocal intraocular lens  trifocal intraocular lens  defocus curve  visual disturbance  spectacle independence
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号