首页 | 本学科首页   官方微博 | 高级检索  
检索        

立位-下体负压时心血管指标的变化
引用本文:沈羡云,孟京瑞,吴斌,李建军,董颀,向求鲁.立位-下体负压时心血管指标的变化[J].航天医学与医学工程,2001,14(1):36-40.
作者姓名:沈羡云  孟京瑞  吴斌  李建军  董颀  向求鲁
作者单位:航天医学工程研究所,
摘    要:目的了解立位 -下体负压 (HUT +LBNP)期间心血管系统的变化 ,确定心律变异和脉图两种方法在评价心血管调节功能中的作用。方法观察 1 6名被试者在 75°头高位倾斜加 - 4kPa下体负压 2 0min期间血压、脉图、心律变异和脑血氧饱和度的变化。结果 ( 1 )HUT +LBNP可引起被试者出现明显的心率、血压、规 -化低频峰功率 (LFn)、LFn/HFn增加 ,脑血氧饱和度、心电T波和规 -化高频峰功率(HFn)下降 ;( 2 )晕厥前出现明显的血压、心率和脑血氧饱和度下降 ;( 3)低耐力组在HUT +LBNP初期的心率明显高于高耐力组 ;( 4 )HUT +LBNP时脉搏波波形发生很大变化 ,无法进行分析。结论HUT +LBNP是一种负荷量较高的立位耐力检查方法 ,可充分暴露被检者在立位中的心血管调节功能 ;脉图检测方法不能作为评价被试者HUT +LBNP耐力的方法。

关 键 词:头立位倾斜  下体负压  心率变异性  脉图  心血管系统
文章编号:1002-0837(2001)01-0036-05
修稿时间:2000年3月27日

Changes of Cardiovascular Indices during Head up Tilt Plus Lower Body Negative Pressure
SHEN Xian yunInstitute of Space Medico Engineering,Beijing ,China,MENG Jing rui,WU Bin,LI Jian jun,DONG Qi,XIANG Qiu lu..Changes of Cardiovascular Indices during Head up Tilt Plus Lower Body Negative Pressure[J].Space Medicine & Medical Engineering,2001,14(1):36-40.
Authors:SHEN Xian yunInstitute of Space Medico Engineering  Beijing  China  MENG Jing rui  WU Bin  LI Jian jun  DONG Qi  XIANG Qiu lu
Institution:Institute of Space Medico-Engineering, Beijing, China.
Abstract:Objective: To understand the change of the cardiovascular function and to evaluate the usefulness of sphygmography and heart rate variability (HRV) spectrum techniques on estimating cardiovascular function during HUP + LBNP. Method: Blood pressure, ECG, cerebral oxygen saturation and sphygmogram of 16 subjects were studied during 75 degrees head up tilt plus lower body negative pressure (HUP + LBNP). Result: (1) During HUP + LBNP, heart rate, blood pressure, normalized low frequency component (LFn), LFn/HFn increased significantly, the cerebral blood oxygen saturation, T wave (ECG), HFn decreased significantly; (2) Blood pressure, heart rate and cerebral blood oxygen saturation decreased significantly in presyncopal state; (3) The heart rate in low tolerance group was higher than that in high tolerance group during the initial stage of HUT + LBNP; (4) The shape of pulse wave changed enormously during HUP + LBNP, so that no analysis could be made. Conclusion: HUP + LBNP was an effective approach to examine the regulatory function of cardiovascular system, and the sphygmogram could not be used in studying the regulatory function of cardiovascular system during HUP + LBNP.
Keywords:head up tilt  lower body negative pressure  heart rate variability  sphygmogram  cardiovascular system
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号