首页 | 本学科首页   官方微博 | 高级检索  
检索        

泛影葡胺和碘海醇、优维显在螺旋CT增强扫描中的对比研究
引用本文:杨学华,高剑波,郭华,李荫太,陈学军,管生,郝桂玲,谢静,杨晓鹏.泛影葡胺和碘海醇、优维显在螺旋CT增强扫描中的对比研究[J].中国医学影像技术,2002,18(6):591-592.
作者姓名:杨学华  高剑波  郭华  李荫太  陈学军  管生  郝桂玲  谢静  杨晓鹏
作者单位:郑州大学第一附属医院放射科,河南,郑州,450052
摘    要:目的 评价 60 %泛影葡胺、碘海醇和优维显 3 0 0临床应用的安全性 ,以最好的效能价格比选择对比剂。方法 分别观察 60 %泛影葡胺、碘海醇及优维显 3 0 0于螺旋CT增强扫描 10 6例、12 0例和 2 3 0例 ,比较其不良反应和图像质量。结果  60 %泛影葡胺、碘海醇与优维显 3 0 0轻、中度不良反应发生率分别为 5 .7%、1.7%和 2 .6%。三种对比剂均未发生严重不良反应。应用三种对比剂所获图像质量均达到诊断要求。结论  60 %泛影葡胺应用于非高危人群是相对安全的

关 键 词:对比剂  螺旋CT  对比研究
文章编号:1003-3289(2002)06-0591-02
收稿时间:2001/12/20 0:00:00
修稿时间:2001年12月20

Comparative Study Among Meglucamine Diatrizoate, Lohexol and Ultravist in Constrast-Enhanced Spiral CT
YANG Xue-hu,GAO Jian-bo,GUO Hu,LI Yin-tai,CHEN Xue-jun,GUAN Sheng,HAO Gui-ling,XIE Jing and YANG Xiao-peng.Comparative Study Among Meglucamine Diatrizoate, Lohexol and Ultravist in Constrast-Enhanced Spiral CT[J].Chinese Journal of Medical Imaging Technology,2002,18(6):591-592.
Authors:YANG Xue-hu  GAO Jian-bo  GUO Hu  LI Yin-tai  CHEN Xue-jun  GUAN Sheng  HAO Gui-ling  XIE Jing and YANG Xiao-peng
Institution:Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China;Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China;Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China;Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China;Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China;Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China;Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China;Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China;Department of Radiology, the First Affilated Hospital of Zhengzhou University, Zhengzhou 450052,China
Abstract:Objective To evaluate the clinical safety of 60% meglucamine diatrizoate, iohexol and ultravist. Contrast media was chosen in optimal price efficiency ratio. Methods One hundred and six patients administered with 60% meglucamine diatrezoate,120patients with iohexol, 230 patients with ultravist were examined by spiral CT. The adverse reactions of contrast and image quality were reviewed and compared with each other. Results The incidence of mild middle adverse reactions of 60% meglucamine diatrezoate, iohexol and ultravist was 5.7%,1.7% and 2.6%, respectively. The image quality of the patients administered with three types of contrast was good. Conclusion 60% meglucamine diatrezoate is relatively safe in patients without hypersensitivity.
Keywords:Contrast media  Spiral CT  Comparative study
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号