摘    要:目的建立工作场所空气中正戊烷、正庚烷、正辛烷的溶剂解吸气相色谱测定方法。方法采用活性炭管采集,二硫化碳解吸,经DB-1毛细管色谱柱分离的气相色谱测定方法。结果该方法正戊烷、正庚烷、正辛烷线性范围分别为0.3~3131、0.3~3418和0.3~7025mg/L,线性方程分别为:Y=1.910X+23.00(r=0.99991)、Y=2.251X-10.64(r=0.99998)和Y=2.305X-34.45(r=0.99997);检出限均达到0.3mg/L;方法的重现性好,相对标准偏差分别为0.2%~0.6%、0.4%~0.8%和0.4%~0.8%;平均解吸效率分别为98.0%~105.2%、99.1%~101.4%和98.7%~99.3%。结论该方法检出限低,精密度和准确度高,可完全适用于工作场所空气中正戊烷、正庚烷、正辛烷的测定。

关 键 词:空气  正戊烷  正庚烷  正辛烷  气相色谱

Simultaneous Determination of N-pentane, N-heptane and N-octane in The Air of Workplace by Gas Chromatography
ZHANG Wen,LI Tian-di,LIN Yi-ran,LI Shuang-feng,YUN Jian-pei,HE Juan-tao,CAI Jin-min,YI Juan. Simultaneous Determination of N-pentane, N-heptane and N-octane in The Air of Workplace by Gas Chromatography[J]. Occupation and Health, 2010, 26(22): 2611-2613
Authors:ZHANG Wen  LI Tian-di  LIN Yi-ran  LI Shuang-feng  YUN Jian-pei  HE Juan-tao  CAI Jin-min  YI Juan
Affiliation:( Shenzhen Occupational Disease Prevention Hospital,Guangdong,518001,China)
Abstract:[Objective]To establish solvent desorption gas chromatographic method for determination of n-pentane、n-heptane and noctane in the air of the workplace.[Methods]Capillary gas chromatography was applied to collect samples with activated carbon tube and separate with DB-1 capillary columns.[Results]Linear limits of the methods was 0. 3 ~ 3131 mg/L for n-pentane,0. 3 ~ 3418 mg/L for n-heptane,and 0. 3 ~ 7025 mg/L for n-octane. The linear equation were Y = 1. 910X + 23. 00( r = 0. 999 91) ,Y = 2. 251X-10. 64( r = 0. 999 98) and Y = 2. 305X-34. 45( r = 0. 999 97) respectively. The limits of detection were 0. 3 mg/L . The determination has a good reproducibility . Their relative standard deviations ( RSD) were 0. 2% ~ 0. 6% ,0. 4% ~ 0. 8% and 0. 4% ~ 0. 8% respectively. The average desorption efficiencies were 98. 0% ~ 105. 2% ,99. 1% ~ 101. 4% and 98. 7% ~ 99. 3% .[Conclusion] The method shows lower detection limit,high accuracy and precision. It is feasible for determination of n-pentane、n-heptane and noctane in workplace air.
Keywords:Air  N-pentane  N-heptane  N-octane  Gas chromatography