不同明度和不同饱和度D-15试验的临床应用
引用本文:黄时洲,吴德正,罗苔青,江福钿,梁炯基,吴乐正,林志定,孙秀茹. 不同明度和不同饱和度D-15试验的临床应用[J]. 眼科学报, 2000, 16(2): 84-86
作者姓名:黄时洲  吴德正  罗苔青  江福钿  梁炯基  吴乐正  林志定  孙秀茹
作者单位:1. 中山医科大学中山眼科中心,广州 510060
2. 中国科学院心理研究所,北京 100101
基金项目:本文受国家自然科学基金资助(基金号:39670256)
摘    要:目的:比较不同明度和不同饱和度D-15试验的临床应用价值。方法:应用Panel D-15试验、Hann氏双D-15试验和北京中国科学院心理研究所中、低饱和度D-15试验「简称CAS-PI D-15试验」对18例(30眼)正常人、19例(38眼)先天性色觉异常、36例(59眼)眼病患者(包括黄斑病、视神经病变、Graves眼病)进行检测。结果:在正常人中,少部分受试眼在低饱和度D-15试验出现小错;

关 键 词:D-15试验 先天性色觉异常 眼病 诊断

The Clinical Application of DifferentBrightness and Different Saturation D-15 Tests
Shizhou Huang,De-Zheng Wu,Taiqin Luo,Futian Jiang,Jiongji Liang,Lezheng Wu Zhiding Lin,Xiuru Sun Zhongshan Ophthalmic Center,Sun Yat-sen University of Medical Sciences,Guangzhou,,China Psychological Institute,Chinese Academy of Sciences,Beijing ,China. The Clinical Application of DifferentBrightness and Different Saturation D-15 Tests[J]. Eye science, 2000, 16(2): 84-86
Authors:Shizhou Huang  De-Zheng Wu  Taiqin Luo  Futian Jiang  Jiongji Liang  Lezheng Wu Zhiding Lin  Xiuru Sun Zhongshan Ophthalmic Center  Sun Yat-sen University of Medical Sciences  Guangzhou    China Psychological Institute  Chinese Academy of Sciences  Beijing   China
Affiliation:Zhongshan Ophthalmic Center, Sun Yat-sen University of Medical Sciences, Guangzhou, 510060, China.
Abstract:Purpose: To compare the clinical application of different brightness and different saturation D-15 tests.Methods: Eighteen normal subjects (30 eyes), 19 cases (38 eyes) of congenital color vision defects and 36 cases (59 eyes) of eye diseases were tested with Panel D-15 test, Hann's double D-15 test, middle and low saturation CAS-PI (Psychological Institute, Chinese Academy of Sciences) D-15 tests.Results: A few of the normal eyes made minor errors in the low saturation D-15 tests. All of the protanopes and deuteranopes could be detected correctly. Protanomalias and deuteranomalias showed normal arrange or some type of abnormal arranges in all of the 5 sets of D-15 tests. In sick eyes, the abnormal rates were the highest in the low saturation D-15 tests and the lowest in Panel D-15 test.Conclusion: The five sets of different brightness and different saturation D-15 tests had similar efficiencies of detecting congenital color vision defects. The abnormal rates of C AS-PI (4/5) D-15 tests and the C AS-PI (2/5) D-15 tests were similar to those of Panel D-15 test and Hann's Double D-15 test. Both tests can be used in the clinical setting. Eye Science 2000; 16: 84 - 86.
Keywords:D-15 test   congenital color vision defect   eye disease  