首页 | 本学科首页   官方微博 | 高级检索  
     

磁导航遥控射频导管消融治疗房室结折返性心动过速的初步体会
引用本文:翟立上,杨兵,徐东杰,张凤祥,居维竹,陈红武,陈明龙,单其俊,邹建刚,陈椿,侯小锋,曹克将. 磁导航遥控射频导管消融治疗房室结折返性心动过速的初步体会[J]. 中华心律失常学杂志, 2010, 14(1): 211-215. DOI: 10.3760/cma.j.issn.1007-6638.2010.03.018
作者姓名:翟立上  杨兵  徐东杰  张凤祥  居维竹  陈红武  陈明龙  单其俊  邹建刚  陈椿  侯小锋  曹克将
作者单位:南京医科大学第一附属医院心血管内科,210029;
摘    要:Objective To evaluate the safety and feasibility of remote radiofrequency catheter ablation of atrioventricular nodal reciprocating tachycardia (AVNRT) using the magnetic navigation system (MNS). Methods A total of 37 patients[female 29, mean age (44 ± 15 )years]with documented AVNRT were enrolled in this study from March 2007 to June 2009. A 4 mm tip magnetic mapping and ablation catheter ( Helios Ⅱ ,Stereotaxis, USA),which was remotely controlled by the MNS (Niobe Ⅱ , Stereotaxis, USA), was used for both mapping and ablation. Conventional slow pathway modification with focal ablation at the fight posterior septum was first performed in all patients. If it was failed, linear lesions at the base of Koch' s triangle was then done. Results After ablation, AVNRT was non-inducible in all 37 patients without any complication except one case experienced transient first degree AV block. Focal ablation was performed in 34 patients, and linear ablation strategy was used in the remaining three cases to achieve the end point. Among all the 37 patients, slow pathway ablation was achieved in 14, whereas slow pathway modification was reached in the remaining 23 cases.The mean procedural time, the RF deliveries, the duration of RF application were ( 120 ± 32) min, (2. 9 ± 1.6)times, ( 130 ± 33 )s,respectively. The total fluoroscopy time and the physician X-ray exposure time were(5.3 ±2. 7)min and(2.9 ± 1.1 ) min,respectively. There was no significant change of the AH interval,the HV interval,and the atrioventricular nodal conduction refractory period after ablation. Compared with the first 18 patients, the mean procedural time, the total fluoroscopy time and the X-ray fluoroscopy time during magnetic navigation were significantly decreased in the later 19 patients (P <0. 001 ). It indicated that the learning curve of remote catheter ablation using the MNS is short. Conclusion Remote catheter ablation using the MNS to cure AVNRT is safe and effective with short learning curve and decreasing X-ray exposure time for interventional physicians.

关 键 词:磁导航系统   遥控   射频导管消融   房室结折返性心动过速   

Ablation of atrioventricular nodal reciprocating tachycardia using remote magnetic navigation system
ZHAI Li-shang,YANG Bing,XU Dong-jie,ZHANG Feng-xiang,JU Wei-zhu,CHEN Hong-wu,CHEN Ming-long,SHAN Qi-jun,ZOU Jian-gang,CHEN Chun,HOU Xiao-feng,CAO Ke-jiang. Ablation of atrioventricular nodal reciprocating tachycardia using remote magnetic navigation system[J]. Chinese Journal of Cardiac Arrhythmias, 2010, 14(1): 211-215. DOI: 10.3760/cma.j.issn.1007-6638.2010.03.018
Authors:ZHAI Li-shang  YANG Bing  XU Dong-jie  ZHANG Feng-xiang  JU Wei-zhu  CHEN Hong-wu  CHEN Ming-long  SHAN Qi-jun  ZOU Jian-gang  CHEN Chun  HOU Xiao-feng  CAO Ke-jiang
Abstract:
Keywords:Magnetic navigation systemRemoteRadiofrequency catheter ablationAtrioventricular nodal reciprocating tachycardia
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号