关 键 词:磁共振胰胆管造影  胰管疾病  胆道疾病  诊断
修稿时间:1999-11-15

Study of Magnetic Resonance Cholangiopancreatography Comparing with Endoscopic Retrograde Cholangiopancreatography in the Diagnosis of Bile Duct and Pancreatic Duct Diseases
Ye Ping,Li Zhao-shen,Xu Guo-ming.Study of Magnetic Resonance Cholangiopancreatography Comparing with Endoscopic Retrograde Cholangiopancreatography in the Diagnosis of Bile Duct and Pancreatic Duct Diseases[J].Chinese Journal of Clinical Gastroenterology,2000,12(4):170-172.
Authors:Ye Ping  Li Zhao-shen  Xu Guo-ming
Institution:Ye Ping ,Li Zhao-shen ,Xu Guo-ming ; (Deparment of Gastroenterology, Changhai Hospital, Second Military Medical University)
Abstract:Purpose: To evaluate magnetic choiangiopancreatography in the diagnosis of bile duct and pancreatic tract diseases. The purpose of this study was to determine in a prospective sensitivity and specificity of MRCP for the evaluation of bile duct and pancreatic tract abnormalities. Methods: 110 patients refered for elective MRCP comparing with ERCP or operation during nine months periods. The presence of dilatation strictures and intraductal abnormalities was recorded sensitivity and specificity of MRCP were determined using findings on ERCP or operation as the gold standard. Results: MRCP images of diagnostic quality were obtained in 110(100%) of the patients. Sensitivity for the detection of bile duct dilatation (n=87), pancreatic duct dilatation (n=30) and intraductal was 85.06%, 53.33% respectivily, sensitivity for the detection of normal bile duct and pancreatic duct was 100%. Conclusions: MRCP has a noninvasive diagnostic modality capable of producing high quality images of the bile duct and pancreatic duct. MRCP has a high sensitivity and specificity in the evaluation of the bile duct and pancreatic ducts base on the data.We believe that the efficacy of MRCP is sufficient to warrant its use in the diagnosis of bile duct and pancreatic tract diseases, but not replace ERCP.
Keywords:Magnetic resonance cholangiopancreatogrephy  Endoscopic retrograde cholangiopancreatography  Pancreatic ductdisease  Bile duct disease  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号