ITI种植体早期负重与传统负重稳定性的比较
引用本文:庄龙飞,张志勇,赖红昌.ITI种植体早期负重与传统负重稳定性的比较[J].上海口腔医学,2007,16(3):251-254.
作者姓名:庄龙飞  张志勇  赖红昌
作者单位:上海交通大学医学院附属第九人民医院·口腔医学院,口腔颅颌面种植科,上海市口腔医学研究所,上海,200011;上海交通大学医学院附属第九人民医院·口腔医学院,口腔颅颌面种植科,上海市口腔医学研究所,上海,200011;上海交通大学医学院附属第九人民医院·口腔医学院,口腔颅颌面种植科,上海市口腔医学研究所,上海,200011
摘    要:目的:应用共振频率分析评价早期负重种植体的稳定性,为种植体早期负重的可行性提供客观依据。方法:50例牙列缺损患者共植入104颗ITISLA表面实心螺纹种植体,随机分为2组,实验组为早期负重组,于术后6周修复;对照组为无负重组,于术后12周修复。在种植体植入术后当天、1周、4周、6周、8周、12周使用无线共振频率分析仪(Osstell Mentor)测定2组种植体的稳定性,所得参数为种植体稳定值(ISO)。采用Minitab统计软件对数据进行t检验.得出各时段2组ISQ值的P值。结果:术后12周,2组种植体的留存率均为100%,2组种植体在各时间段的ISQ值均无显著差异(P〉0.05),整体变化趋势相同:表现为初期稳定性均较高,于第1周至第4周下降,第6周逐步上升,其后稳定性基本保持不变或略有上升。随访期(修复后6个月)间,2组种植体的留存率均为100%。结论:ITISLA表面种植体早期负载是可行的。

关 键 词:牙种植体  共振频率分析  早期负重  稳定性
文章编号:1006-7248(2007)03-0251-04
收稿时间:2007-01-16
修稿时间:2007-01-162007-04-16

Comparison of the stability between early-loaded and conventionally-loaded ITI implants
ZHUANG Long-fei,ZHANG Zhi-yong,LAI Hong-chang.Comparison of the stability between early-loaded and conventionally-loaded ITI implants[J].Shanghai Journal of Stomatology,2007,16(3):251-254.
Authors:ZHUANG Long-fei  ZHANG Zhi-yong  LAI Hong-chang
Institution:Department of Oral and Cranio-maxillofacial Implantology, Ninth People's Hospital,College of Stomatology, School of Medicine, Shanghai Jiao Tong University, Shanghai Research Institute of Stomatology, Shanghai 200011,China.
Abstract:PURPOSE: To evaluate the feasibility of early implant loading by observation of the implant stability of early-loaded ITI implants using resonance frequency analysis (RFA). METHODS: 104 ITI SLA implants in 50 patients were randomly divided into 2 groups according to different loading time. In the experimental group, plants were loaded 6 weeks after surgery; in the control group, implants were loaded 12 weeks after installation. RFA was taken at 0,1,4,6,8,12 weeks after surgery for implants in both groups to get ISQ(implant stability quotient) values.Student's t test was used to calculate P values for ISQ at all time points by Minitab Release 14.13. RESULTS: No implant failed within the 12 weeks. No significant difference in ISQ values was found between the two groups at all time points(P>0.05).The 2 groups had the same changing mode of ISQ: a relatively high primary stability, a decrease from 1 to 4 weeks, a consequent increase after 6 weeks and a relative stability or a slight increase afterwards. The survival rate for both group during the 6 months follow-up is 100%. CONCLUSIONS: Early loading of ITI SLA implant should be predictable.
Keywords:Dental implants  Resonance frequency analysis  Early loading  Stability