实时心电监测在室间隔缺损堵闭术中的应用
引用本文:陆颖,盛锋,吴琳,刘芳,黄国英. 实时心电监测在室间隔缺损堵闭术中的应用[J]. 实用心电学杂志, 2010, 19(2): 109-111
作者姓名:陆颖  盛锋  吴琳  刘芳  黄国英
作者单位:复旦大学附属儿科医院,上海,200032
摘    要:目的探讨实时心电监测在室间隔缺损(VSD)堵闭治疗中的应用价值。方法 65例均经左室造影证实为VSD者接受堵闭术治疗,并选手术前心电图检查基本正常者为研究对象。在堵闭术中及术后3~5d予实时心电监测,观察有无心律失常尤其是恶性心律失常的发生,并据此及时对应治疗甚至终止手术。随后跟踪随访心电情况1年。结果 65例在术中或术后发生心律失常事件13例,发生率20%。其中6例在建立股动静脉轨道过程中,出现三度房室阻滞(AVB)2例、完全性左束支阻滞(CLBBB)2例、CLBBB并三度AVB 1例、室性心动过速(VT)1例。评估术后可能发生严重并发症的风险后放弃堵闭。另7例心律失常中5例术中出现完全性右束支阻滞(CRBBB)或一过性不完全性右束支阻滞(ICRBBB),于堵闭器释放后均自行恢复正常;2例术后出现三度AVB伴短阵VT或ICLBBB,及时应用激素治疗2~3d后心律失常消失。跟踪随访期未见异常。结论在VSD堵闭治疗中,心律失常的发生率较高。实时心电监测可及时发现术中、术后心律失常的发生,并指导临床治疗。

关 键 词:心电监测  心律失常  堵闭治疗  室间隔缺损

Application of real-time electrocardiogram monitor in occlusion of ventricular septal defect
LU Ying,SHENG Feng,WU Lin,LIU Fang,HUANG Guoying. Application of real-time electrocardiogram monitor in occlusion of ventricular septal defect[J]. Journal of Practical Electrocardiology JS, 2010, 19(2): 109-111
Authors:LU Ying  SHENG Feng  WU Lin  LIU Fang  HUANG Guoying
Affiliation:LU Ying ,SHENG Feng, WU Lin, LIU Fang, HUANG Guoying
Abstract:Objective To evaluate the use of real-time electrocardiogram(ECG) monitor in transcatheter occlusion of ventricular septal defect(VSD).Methods 65 patients including 3 residual VSD after surgical repair and 62 membranous ventricular septal defect were performed transcatheter occlusion in Children's Hospital of Fudan University from 2002 to 2008.Real-time ECG(GE Prucka CardioLab 4000 workstation) monitor was routinely used during the procedure.Results All VSD cases were confirmed by left ventricle angiogram.Arrhythmia happened in 13 of 65 cases(20%) during or after the operation.The occlusion failed in 6 cases due to recurrent severe arrhythmia detected by real-time ECG monitor when established the femoral A-V wire-track:Ⅲ degree atrioventricular bundle block(Ⅲ° AVB),complete left bundle branch block(CLBBB),Ⅲ?AVB combined with CLBBB,and intraventricular block combined with ventricular tachycardia(VT)in 2,2,1 and 1 case,which may result in persistent arrhythmia after occlusion.Arrhythmia were detected in 7 of 59 cases(90.7%) with successful occlusion:4 cases had complete right bundle branch block(CRBBB)and recovered after releasing the occluder,3 cases had transient incomplete right bundle branch block(ICRBBB)when the A-V wire-track was established,then followed with Ⅲ° AVB with non-persistent ventricular tachycardia(VT)or CLBBB after the occlusion,in which the arrhythmia disappeared in 2~3 days with steroid therapy.Conclusion The prevalence of arrhythmia is much higher in transcatheter closure of VSD than that in other interventional procedures.Real-time ECG monitor is valuable in detecting arrhythmia during and after the occlusion.
Keywords:Electrocardiogram monitorArrhythmiaOcclusionVentricular septal defect