首页 | 本学科首页   官方微博 | 高级检索  
检索        

上颌窦相关解剖结构的锥形束CT影像学特征
作者姓名:李明霞  王光平  王虎
作者单位:1 泸州医学院附属口腔医院放射科,四川省泸州市 646000 2 泸州医学院附属口腔医院正畸科,四川省泸州市 646000 3 四川大学华西口腔医院放射科,四川省成都市 610041
摘    要:背景:为了避免相关并发症的发生以及方便手术方式的选择,上颌窦提升术前准确了解上颌窦区域的解剖结构特点显得尤为重要。 目的:通过牙科锥形束CT影像研究上颌窦区的解剖结构特点,为上颌窦提升种植手术提供参考。 方法:选取符合标准的249例成年人的锥形束CT影像资料,在选择的层面上测量左侧上颌窦内壁的近远心距离和上颌窦的宽度,并对上颌窦内分嵴的情况和上颌窦壁血管的走行特点进行初步观察和分析。 结果与结论:上颌窦内壁的近远心距离的总平均值为(32.0±3.81) mm,上颌窦的宽度总平均值为(21.70±5.16) mm。不同性别、年龄段上颌窦内壁的近远心距离和上颌窦的宽度差别无显著性意义(P > 0.05),上颌窦内分嵴的发生率为33%(78/249);锥形束CT能清晰准确的显示出上颌窦壁血管的分布和走行特点。说明牙科锥形束CT能够全面并准确反映上颌窦的解剖结构,对决定上颌窦提升术的适应证和手术方式以及避免或降低手术并发症的发生率具有重要意义。

关 键 词:组织构建  组织构建临床实践  锥形束CT  上颌窦  上颌窦提升术  牙种植  解剖结构  
收稿时间:2012-03-09

Anatomical structure of human maxillary sinus: Cone-beam CT analysis
Authors:Li Ming-xia  Wang Guang-ping  Wang Hu
Institution:1 Department of Oral Radiology, Dental Hospital of Luzhou Medical College, Luzhou 646000, Sichuan Province, China 2 Department of Orthodontics, Dental Hospital of Luzhou Medical College, Luzhou 646000, Sichuan Province, China 3 Department of Oral Radiology, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan Province, China
Abstract:BACKGROUND:In order to avoid related complications and to facilitate the choice of surgical approaches, it is particularly important to understand the anatomic characteristics of the maxillary sinus before maxillary sinus augmentation. OBJECTIVE:To investigate the anatomic characteristics of human maxillary sinus based on cone-beam CT imaging for providing some reference related to sinus floor elevation and implant insertion.   METHODS:Cone-beam CT imaging data from 249 adults were selected and analyzed. The length (internal wall) and width of the maxillary sinus were measured, and the incidence of maxillary sinus septa and the characteristics of the maxillary sinus vessels were investigated and analyzed preliminarily. RESULTS AND CONCLUSION:The mean length (internal wall) and width of maxillary sinus were (32.0±3.81) and (21.70±5.16) mm, respectively. No significant differences were noted in the length and width of maxillary sinus based on sex or age (P > 0.05). The incidence of maxillary sinus septa was 33% (78/249). Moreover, the distribution and characteristics of the maxillary sinus vessels could be seen clearly and accurately on cone-beam CT three-dimensional images. These findings indicate that cone-beam CT images can show anatomical structures of the maxillary sinus fully and accurately, and the use of cone-beam CT is advantageous and mandatory to determine surgical indications and approaches, and avoid or reduce the incidence of surgical complications of maxillary sinus floor elevation.
Keywords:tissue construction  clinical practice in tissue construction  cone-beam CT  maxillary sinus  maxillary sinus augmentation  dental implants  anatomical structures  
点击此处可从《》浏览原始摘要信息
点击此处可从《》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号