Three-dimensional time-of-flight (3D TOF) magnetic resonance angiography (MRA) and contrast-enhanced MRA of intracranial aneurysms treated with platinum coils |
| |
Authors: | Wikström J Ronne-Engström E Gal G Enblad P Tovi M |
| |
Affiliation: | a Departments of Radiology and Neurosurgery, Uppsala University Hospital, Uppsala, Sweden |
| |
Abstract: | Background: Contrast-enhanced magnetic resonance angiography (CE-MRA) is less prone to flow-related signal intensity loss than three-dimensional time-of-flight (3D TOF) MRA and may therefore be more sensitive for detection of residual patency in platinum coil-treated intracranial aneurysms.
Purpose: To compare MRA and CE-MRA in the follow-up of intracranial aneurysms treated with platinum coils.
Material and Methods: CE-MRA and 3D TOF MRA (pre- and postcontrast injection) of the intracranial vasculature was performed at 1.5T in 38 patients (47 aneurysms) referred for DSA in the follow-up of coiled intracranial aneurysms.
Results: DSA showed aneurysm patency in 22/47 investigations. Patent aneurysm components were observed with CE-MRA in 18/22 cases, and with 3D TOF MRA in 21/22 cases. There was no significant difference in patent aneurysm component size between CE-MRA and 3D TOF MRA. In addition, CE-MRA showed six, 3D TOF MRA before contrast injection showed seven, and 3D TOF MRA after contrast injection showed eight cases with patent aneurysm components not observed on DSA.
Conclusion: 3D TOF MRA was highly sensitive for detection of patent aneurysm components, and at least as sensitive as CE-MRA. Residual aneurysm patency seems to be better visualized with MRA than with DSA in some cases. |
| |
Keywords: | Adults aneurysms CNS contrast agents intravenous MR angiography vascular |