Gliding characteristics and gap formation for locking and grasping tendon repairs: a biomechanical study in a human cadaver model
Authors:Tanaka Tatsuro  Amadio Peter C  Zhao Chunfeng  Zobitz Mark E  Yang Chao  An Kai-Nan
Institution:Biomechanics Laboratory, Department of Orthopedics, Mayo Clinic Rochester, 200 First St SW, Rochester, MN 55905, USA.
Abstract:PURPOSE: The purpose of this study was to compare the frictional characteristics and mechanical properties of various locking and grasping suture techniques in a human in vitro model of flexor tendon repair. METHODS: Forty-five cadaveric human flexor digitorum profundus tendons were transected in zone II and repaired using 1 of 5 core suture methods (n = 9 per group): either grasping (modified grasping Kessler, modified Lee) or locking (Pennington, modified Pennington, locking Lee) loop suture techniques. All repairs used 4-0 Supramid looped core suture and an epitenon running suture of 6-0 nylon. Gliding resistance at the tendon-pulley interface was measured along with failure strength and gap formation. The force to produce 0.5-, 1.0-, 1.5-, and 2.0-mm gaps were measured. RESULTS: One of the locking repairs, the locking Lee, had a gliding resistance significantly higher than that of one of the grasping repairs (modified grasping Kessler) and the other 2 locking repairs (Pennington, modified Pennington) (p <.05). There was no significant difference between the other grasping (modified Kessler, modified Lee) and locking (Pennington, modified Pennington) suture configurations (p =.21). The maximum force of one of the locking repairs, the modified Pennington repair (48.0 N; standard deviation, 3.9) was significantly higher than the other locking and grasping repairs (p <.05). The force required to produce more than 1.5 mm of gap for the modified Pennington repair was also significantly higher than that for some of the other grasping (modified Kessler, modified Lee) and locking (Pennington) repairs (p <.05). CONCLUSIONS: The lack of significant difference in gliding resistance among the similarly designed modified grasping Kessler, Pennington, and modified Pennington repairs (overall mean, 0.87 N; standard deviation, 0.16) suggests that the locking loop configuration itself does not adversely affect tendon gliding resistance. The modified Pennington repair increased not only ultimate strength but also resistance to gap formation more than 1.5 mm.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号