首页 | 本学科首页   官方微博 | 高级检索  
检索        


Effects of long-term water storage on the microtensile bond strength of five experimental self-etching adhesives based on surfactants rather than HEMA
Authors:Cesar Henrique Zanchi  Eliseu Aldrighi Münchow  Fabrício Aulo Ogliari  Rodrigo Varella de Carvalho  Stefano Chersoni  Carlo Prati  Flávio Fernando Demarco  Evandro Piva
Institution:1. Department of Operative Dentistry, School of Dentistry, Federal University of Pelotas, Rua Gon?alves Chaves, 457, Pelotas, RS, Brazil, 96015-560
2. Department of Restorative Dentistry, School of Dentistry, University of North Parana, Londrina, Paraná, Brazil
3. Department of Endodontics, School of Dentistry, University of Bologna, Bologna, BO, Italy
Abstract:

Objectives

The purpose of this study is to evaluate the hypothesis that replacing 2-hydroxyethyl methacrylate (HEMA) for surfactant dimethacrylates (SD) does not affect the immediate and long-term microtensile bond strength (μTBS) of experimental two-step self-etch HEMA-free adhesive systems applied on dentin.

Materials and methods

Five experimental HEMA-free two-step self-etching systems containing different SD (ethoxylated bisphenol A diglycidyl dimethacrylate (Bis-EMA 10, B10), Bis-EMA 30 (B30), poly-ethyleneglycol (400) dimethacrylate (PEG 400, P400), PEG 1000 (P1000), and PEG 400 urethane dimethacrylate (UDMA) (UP400)) and a HEMA-containing system (control) (HA) were formulated. Specimens were subjected to the μTBS test after 24 h and 6 and 12 months of storage. Data (in megapascals) were analyzed by Kruskal–Wallis and Dunn tests (α?=?0.05).

Results

Medians of the μTBS data after 24 h of storage are: HA?=?57.2A, B10?=?26.2BC, B30?=?24.0C, P400?=?32.6BC, P1000?=?37.3B, and UP400?=?57.9A; after 6 months are: HA?=?47.9A, B10?=?18.5B, B30?=?7.8C, P400?=?16.1B, P1000?=?14.6BC, and UP400?=?51.6A; and after 12 months are: HA?=?31.2A, B10?=?15.2B, B30?=?9.0B, P400?=?9.1B, P1000?=?13.3B, and UP400?=?35.7A. Between the HEMA-free groups, the adhesive system formulated with PEG 400 UDMA produced similar μTBS to the HEMA-containing group. Also, the storage of specimens decreased the μTBS (p?<?0.05).

Conclusion

Replacing HEMA for PEG 400 UDMA in an adhesive system formulation generated a satisfactory μTBS to dentin.

Clinical relevance

Surfactant dimethacrylates have a potential use in the development of HEMA-free self-etching adhesive systems, which are more chemically stable.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号