首页 | 本学科首页   官方微博 | 高级检索  
     


Hydroxyapatite-coated external-fixation pins. The effect on pin loosening and pin-track infection in leg lengthening for short stature
Authors:Pizà G  Caja V L  González-Viejo M A  Navarro A
Affiliation:Universitari Germans Trias i Pujol, Badalona and Hospital Universitari Vail D'Hebron, Barcelona, Spain.
Abstract:Pin loosening and infection are inherent complications of external fixation. This study deals with their effects of using either hydroxyapatite (HA)-coated or uncoated external fixation pins in leg-lengthening procedures on patients of short stature. We used HA-coated pins on one side and uncoated pins on the other (randomly determined) in 28 bilateral lengthenings undertaken in 23 patients. A total of 322 pins was used. The mean implantation time was 530 days and the mean lengthening achieved was 78% of initial bone length. Mean extraction torque was 7611.6 Nmm degree(-1) for HA-coated and 85.4 Nmm degree(-1) for uncoated pins (p < 0.001). The rate of pin loosening was 4% (7/161) for HA-coated and 80% (129/161) for uncoated pins (p < 0.001). There was no statistically significant difference in the incidence of pin-track infection between the two groups. The use of HA coating appears to be an effective method of reducing the incidence of pin loosening in external fixation with a long implantation time and for mechanically highly stressed procedures such as leg lengthening for short stature.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏