首页 | 本学科首页   官方微博 | 高级检索  
     

扣带回体积的标准化测量
引用本文:张超,陈楠,王星,卓彦,陈霖,李坤成. 扣带回体积的标准化测量[J]. 中国医学影像技术, 2012, 28(1): 1-5
作者姓名:张超  陈楠  王星  卓彦  陈霖  李坤成
作者单位:1. 中国核工业北京401医院放射科,北京,102413
2. 首都医科大学宣武医院放射科,北京,100053
3. 中国科学院生物物理研究所脑与认知科学国家重点实验室,北京,100101
基金项目:国家高技术研究发展计划(863计划)项目(2006AA02z391)、科技部基金项目(2005CB522800、2004CB318101)、国家自然科学基金(30621004、30870697)。
摘    要:目的 比较扣带回体积与校正因素的关系,为扣带回结构提供标准化的测量方法.方法 对627名18~60岁中国正常成年志愿者行全脑MR容积扫描,应用3D体积分析软件手工勾绘ROI,测量扣带回的体积,并分别以颅内容积(TIV)和脑体积(WBV)进行校正.对校正前、后的扣带回体积分别与TIV和WBV进行相关性分析.结果 校正前和TIV、WBV校正后的扣带回体积:男性分别为(21.01±2.31)ml、(21.11±2.57)ml、(21.06±2.34)ml,女性分别为(19.72±2.31)ml、(19.79±2.28)ml、(19.74±2.04)ml;左侧分别为(9.71±1.54)ml、(9.77±1.61)ml、(9.75±1.54)ml,右侧分别为(10.64±1.58)ml、(10.69±1.53)ml、(10.67±1.45) ml.校正前的扣带回体积与TIV的相关性不强(男、女:r=0.225、0.385;左、右侧:r=0.229、0.366;P均<0.05),与WBV的相关性略高(男、女:r=0.329、0.473;左、右侧:r=0.381、0.419;P均<0.05);校正后的扣带回体积与TIV仍有相关性(男、女:r=-0.378、-0.379;左、右侧:r=-0.368、-0.300;P均<0.05),与WBV相关性降低(男、女:r=-0.297、-0.156;左、右侧:r=-0.285、-0.197;P均<0.05).结论 扣带回体积与TIV和WBV均有一定相关性;WBV校正效果优于TIV.

关 键 词:扣带回  磁共振成像  人体测量术
收稿时间:2011-08-24
修稿时间:2011-09-20

Standardized measurement of cingulate gyrus volume
ZHANG Chao,CHEN Nan,WANG Xing,ZHUO Yan,CHEN Lin and LI Kun-cheng. Standardized measurement of cingulate gyrus volume[J]. Chinese Journal of Medical Imaging Technology, 2012, 28(1): 1-5
Authors:ZHANG Chao  CHEN Nan  WANG Xing  ZHUO Yan  CHEN Lin  LI Kun-cheng
Affiliation:Department of Radiology, Beijing 401 Hospital of China Nuclear Industry, Beijing 102413, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China;State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics, Chinese Academy of Sciences, Beijing 100101, China;State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics, Chinese Academy of Sciences, Beijing 100101, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China
Abstract:Objective To assess the correlations of cingulate gyrus volume with corrected factor, in order to provide standard volumetric method for cingulate gyrus. Methods Totally 627 Chinese healthy volunteers (aged from 18 to 60) underwent brain three-dimensional MR scan. Cingulate gyrus volumes were manually measured with ROI using 3D volume analysis software, and were corrected by total intracranial volume (TIV) and whole brain volume (WBV), respectively. Correlation of uncorrected and corrected cingulate gyrusvolumes with TIV and WBV were analyzed, respectively. Results Uncorrected and corrected cingulate gyrus volume by TIV and WBV was (21.01±2.31)ml, (21.11±2.57)ml, (21.06±2.34)ml respectively for male, (19.72±2.31)ml, (19.79±2.28)ml, (19.74±2.04)ml respectively for female, (9.71±1.54)ml, (9.77±1.61)ml, (9.75±1.54)ml respectively for left side, (10.64±1.58)ml, (10.69±1.53)ml, (10.67±1.45)ml respectively for right side. Uncorrected cingulate gyrus volumes had lower correlation with TIV (male, female: r=0.225, 0.385; left, right: r=0.229, 0.366; all P<0.05), and higher correlation with WBV (male, female: r=0.329, 0.473; left, right: r=0.381, 0.419; all P<0.05). Corrected cingulate gyrus volumes were correlated with TIV (male, female: r=-0.378, -0.379; left, right: r=-0.368, -0.300; all P<0.05), and had lower correlation with WBV (male, female: r=-0.297, -0.156; left, right: r=-0.285, -0.197; all P<0.05). Conclusion There is correlation between cingulate gyrus volume and TIV or WBV. Cingulate gyrus volume corrected with WBV is better.
Keywords:Gyrus cinguli  Magnetic resonance imaging  Anthropometry
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号