首页 | 本学科首页   官方微博 | 高级检索  
     


A Deep Learning Tool for Automated Radiographic Measurement of Acetabular Component Inclination and Version After Total Hip Arthroplasty
Authors:Pouria Rouzrokh  Cody C. Wyles  Kenneth A. Philbrick  Taghi Ramazanian  Alexander D. Weston  Jason C. Cai  Michael J. Taunton  David G. Lewallen  Daniel J. Berry  Bradley J. Erickson  Hilal Maradit Kremers
Affiliation:1. Department of Radiology, Mayo Clinic, Radiology Informatics Laboratory, Rochester, MN;2. Department of Health Sciences Research, Mayo Clinic, Rochester, MN;3. Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
Abstract:BackgroundInappropriate acetabular component angular position is believed to increase the risk of hip dislocation after total hip arthroplasty. However, manual measurement of these angles is time consuming and prone to interobserver variability. The purpose of this study was to develop a deep learning tool to automate the measurement of acetabular component angles on postoperative radiographs.MethodsTwo cohorts of 600 anteroposterior (AP) pelvis and 600 cross-table lateral hip postoperative radiographs were used to develop deep learning models to segment the acetabular component and the ischial tuberosities. Cohorts were manually annotated, augmented, and randomly split to train-validation-test data sets on an 8:1:1 basis. Two U-Net convolutional neural network models (one for AP and one for cross-table lateral radiographs) were trained for 50 epochs. Image processing was then deployed to measure the acetabular component angles on the predicted masks for anatomical landmarks. Performance of the tool was tested on 80 AP and 80 cross-table lateral radiographs.ResultsThe convolutional neural network models achieved a mean Dice similarity coefficient of 0.878 and 0.903 on AP and cross-table lateral test data sets, respectively. The mean difference between human-level and machine-level measurements was 1.35° (σ = 1.07°) and 1.39° (σ = 1.27°) for the inclination and anteversion angles, respectively. Differences of 5? or more between human-level and machine-level measurements were observed in less than 2.5% of cases.ConclusionWe developed a highly accurate deep learning tool to automate the measurement of angular position of acetabular components for use in both clinical and research settings.Level of EvidenceIII.
Keywords:total hip arthroplasty  acetabular component angle  inclination angle  anteversion angle  artificial intelligence  deep learning
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号