首页 | 本学科首页   官方微博 | 高级检索  
检索        


Ceramic Coating in Cemented Primary Total Knee Arthroplasty is Not Associated With Decreased Risk of Revision due to Early Prosthetic Joint Infection
Authors:Alexander W Grimberg  Thomas M Grupp  Johanna Elliott  Oliver Melsheimer  Volkmar Jansson  Arnd Steinbrück
Institution:1. Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Munich, Germany;2. German Arthroplasty Registry (EPRD Deutsche Endoprothesenregister gGmbH), Berlin, Germany;3. Department of Orthopaedic Surgery and Traumatology, St Vinzenz Hospital, Dinslaken, Germany;4. Orthopaedic Surgical Competence Center Augsburg (OCKA), Augsburg, Germany
Abstract:BackgroundProsthetic joint infection (PJI) is one of the most frequent and devastating causes of short-term revision total knee arthroplasty (TKA). In vitro evidence suggests ceramic surfaces demonstrate resistance to biofilm, but the clinical effect of bearing surface modifications on the risk of PJI remains unclear. This premier registry-based study examines the influence of ceramic bearing surface coatings on the outcome in cemented primary TKA.MethodsIn total, 117,660 cemented primary TKAs in patients with primary osteoarthritis recorded in the German arthroplasty registry since 2012 were followed up for a maximum of 3 years. The primary endpoint was risk of revision for PJI on ceramic coated and uncoated cobalt-chromium-molybdenum femoral components. Propensity score matching for age, gender, obesity, diabetes mellitus, depression and Elixhauser comorbidity index, and substratification on common design twins with and without coating was performed.ResultsIn total, 4637 TKAs (85.1% female) with a ceramic-coated femoral component were identified, 42 had been revised for PJI and 122 for other reasons at 3 years. No survival advantage due to the risk of revision for PJI could be determined for ceramic-coated components. Revision for all other reasons demonstrated a significant higher rate for TKAs with ceramic-coated components. However, the results of this were confounded by a strong prevalence (20.7% vs 0.3%) of metal sensitivity in the ceramic-coated group.ConclusionNo evidence of reduced risk for PJI due to ceramic-coated implants in cemented primary TKA was found. Further analysis for revision reasons other than PJI is required.
Keywords:prosthetic joint infection  ceramic coating  biofilm  arthroplasty registry  bearing surface
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号