低管电压、低浓度碘对比剂(双低)在头颈 CTA 检查中的应用 |
| |
引用本文: | 王玉屏,王龙胜,郑穗生,邹立巍. 低管电压、低浓度碘对比剂(双低)在头颈 CTA 检查中的应用[J]. 安徽医科大学学报, 2015, 0(5) |
| |
作者姓名: | 王玉屏 王龙胜 郑穗生 邹立巍 |
| |
作者单位: | 安徽医科大学第二附属医院放射科,合肥,230601 |
| |
基金项目: | 安徽高校省级科学研究项目 |
| |
摘 要: | 目的:探讨低管电压、低浓度碘对比剂(双低)在头颈 CT 血管造影(CTA)检查中的应用效果。方法选取60例行头颈 CTA 检查的健康志愿者作为研究对象,并随机分为双低组和常规组,每组30例,双低组采用低管电压、低浓度碘对比剂头颈 CTA 检查,常规组实施常规 CTA 检查,比较两组受检者的图像质量、CT 值等级、辐射剂量等。结果双低组不同兴趣区(ROI)的 CT 值与常规组差异无统计学意义(P >0.05);双低组在右大脑中动脉、左大脑中动脉中的图像质量评分稍低于常规组(P <0.05);在其他 ROI 中,两组的图像质量评分比较,差异无统计学意义(P >0.05);两组图像质量的主观评分结果差异无统计学意义(P >0.05);双低组的体型特异性剂量估计值、剂量长度乘积值均显著低于常规组(P <0.05)。结论使用低管电压、低浓度对比剂进行头颈 CTA 检查,能够在不影响图像质量的基础上降低对比剂用量、减少辐射剂量,具有重要的推广应用价值。
|
关 键 词: | 头颈 CTA 低浓度碘对比剂 低管电压 辐射剂量 |
Lower tube voltage,low concentration of iodine contrast agent (double) application in head and neck CTA examination |
| |
Abstract: | Objective To investigate the low tube voltag, low concentrations of iodine contrast agent (double low) application results in the head-neck CT angiography (CTA) examination. Methods Sixty volunteers, selected as research objects to receive CTA, were randomly divided into a double-low test group and a conventional test group, with 30 volunteers in each group. For the double-low test group, the head-neck CTA examination was conducted by means of lower tube voltage and lower-concentration iodinated contrast agent, while the conventional test group was given conventional CTA examination. After the examination, the two groups were mutually compared in terms of im-age quality, CT value level, radiation dose, and so on. Results Two different groups interested in the low zone (ROI) and conventional CT values had no differences (P > 0. 05); double low set in the right middle cerebral ar-tery, the left middle cerebral artery in image quality score was slightly lower than that of the conventional group (P< 0. 05); ROI in the other two groups of image quality scores and subjective image quality scores, there was no significant difference (P > 0. 05); SSDE double low group, DLP values were significantly lower than that of the conventional group(P < 0. 05). Conclusion The use of lower tube voltage and lower-concentration contrast agent for the head-neck CTA examination can, without affecting image quality, reduce the dose of contrast agent and that of radiation, thus being worthy of application and promotion. |
| |
Keywords: | head and neck CTA low concentration of iodine contrast agent low voltage radiation dose |
本文献已被 万方数据 等数据库收录! |
|