In-vivo quantification of myocardial Na-K pump rate during beta-adrenergic stimulation of intact pig hearts
Authors:O Ellingsen  O M Sejersted  O A Vengen  A Ilebekk
Institution:Institute for Experimental Medical Research, University of Oslo, Norway.
Abstract:Maintenance of adequate electrical activity of the heart depends critically on the ability of the Na-K pump to compensate for normal passive sodium and potassium fluxes. Using sudden injections of 3H]ouabain into the left coronary artery in anaesthetized open-chest pigs, we monitored transient changes in myocardial potassium balance by PVC-valinomycin mini-electrodes. When related to the number of pumps blocked and fractional inhibition, these data provided estimates of total Na-K pump capacity as well as actual pump rate and perturbations of the Na-K balance. Experiments were performed in hearts with and without intracoronary isoprenaline infusion (2.5 nmol min-1). After injection of 120 nmol 3H]ouabain into the left coronary artery, myocardial 3H]ouabain concentrations were 118 (74-178) and 103 (76-145) pmol g-1 and total concentrations of 3H]ouabain binding sites were 893 (752-1076) and 785 (691-877) pmol g-1 (median, 95% confidence interval) in isoprenaline-treated and control hearts respectively (differences not significant). The 3H]ouabain injection caused a net potassium release of 81 (56-132) and 43 (23-75) mumol 100 g-1 (median, 95% confidence interval) in isoprenaline-treated and control hearts respectively (n = 6-8; significance of difference, P = 0.03). Na-K pump rate estimated from mono-exponential release curves was 6363 (3942-10,858) K+ ions min-1 site-1 during beta-adrenoceptor stimulation and 2514 (1380-4322) in control (significance of difference, P = 0.03). This corresponds to 40 and 16%, respectively, of the maximum possible pump rate determined from ATP hydrolysis. Comparison of accumulated potassium release and relative Na-K pump rate indicates that catecholamines enhance the sensitivity of the Na-K pump for intracellular sodium.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号