首页 | 本学科首页   官方微博 | 高级检索  
检索        

基于切伦科夫效应的裸鼠甲状腺131I多模态显像
引用本文:胡振华,梁继民,屈晓超,杨卫东,马晓伟,汪静,田捷.基于切伦科夫效应的裸鼠甲状腺131I多模态显像[J].中华核医学杂志,2012,32(1):29-31.
作者姓名:胡振华  梁继民  屈晓超  杨卫东  马晓伟  汪静  田捷
作者单位:1. 710071, 西安电子科技大学、生命科学技术学院
2. 第四军医大学西京医院核医学科
3. 710071 西安电子科技大学、生命科学技术学院;中国科学院自动化研究所
基金项目:国家重点基础研究发展计划(973计划)(2011CB707702);国家自然科学基金(81000632,30900334,81101083,81101084)
摘    要:目的 采用切伦科夫发光断层成像(CLT)和γ显像进行裸鼠甲状腺摄取131I的多模态成像,探索CLT与γ显像之间的相关性.方法 先对4只裸鼠体质量(21±3)g]尾静脉注射1.67×107 Bq 131I,在注药后0.5、3、12及24h均分别行CLT和γ显像.采用基于漫射方程(DE)的切伦科夫光源重建方法重建裸鼠体内131I的生物分布及在不同采集时间点甲状腺摄取131I的切伦科夫光的功率.对采集的γ显像图像勾画ROI,获得γ计数的平均值,对CLT 1311的切伦科夫光的功率和γ显像获取的γ计数行直线相关分析.结果 甲状腺摄取131I的切伦科夫光的功率在0.5、3、12和24h分别为7.80×10-3、1.62×10-12、2.20×10 - 12和2.68×10-12 W.甲状腺摄取131I的切伦科夫光的功率随放射性药物注射时间的延长而逐渐增加.γ显像结果表明131I在裸鼠腹部的摄取逐渐降低,而在甲状腺的摄取越来越高,CLT与γ显像结果具有较好的相关性(r2 =0.7620,P<O.05).结论 CLT具有临床甲状腺成像、甲状腺疾病诊断和疗效判断的潜力.

关 键 词:切伦科夫光学成像  碘放射性同位素  甲状腺  小鼠    放射性核素显像

Multimodality imaging of ^131I uptake in nude mice thyroid based on Cerenkov radiation
HU Zhen-hua , LIANG Ji-min , QU Xiao-chao , YANG Wei-dong , MA Xiao-wei , WANG Jing , TIAN Jie.Multimodality imaging of ^131I uptake in nude mice thyroid based on Cerenkov radiation[J].Chinese Journal of Nuclear Medicine,2012,32(1):29-31.
Authors:HU Zhen-hua  LIANG Ji-min  QU Xiao-chao  YANG Wei-dong  MA Xiao-wei  WANG Jing  TIAN Jie
Institution:. Life Sciences Research Center, School of Life Sciences and Technology, Xidian University, Xi'an 710071, China
Abstract:Objective To perform the multimodality ^131I thyroid imaging using Cerenkov lumines- cence tomography (CLT) and gamma imaging, and to compare the results of CLT and gamma imaging. Meth- ods The nude mice ( n = 4, mass : (21±3) g) were injected with 1.67 ×107 Bq ^131 I. CLT and gamma im- aging were acquired at 0. 5, 3, 12 and 24 h after the injection. Three-dimensional biodistribution of ^131I uptake in thyroid was reconstructed using Cerenkov source reconstruction method based on the diffusion equa- tion (DE), and the reconstructed power of ^131I in different acquisition time points was obtained. Additional- ly, the ROIs were drawn over the gamma images of the mouse neck, and the counts were read. The correla-tion between the reconstructed power of CLT and gamma ray counts of gamma imaging was analyzed. Re- suits The power of ^131I uptake in thyroid at 0. 5, 3, 12 and 24 h were 7. 80 ×10^-13, 1.62×10^-12,2.20× 10-12 and 2. 68×10^-12 W, respectively. CLT results showed that reconstructed power increased with the increasing of acquisition time. Gamma imaging results indicated that ^131I uptake decreased in abdomen and in- creased in thyroid with the collection time. The results of CLT were consistent with that of gamma imaging (r^2 = 0.7620, P 〈 0. 05 ). Conclusion CLT has the potential to identify and monitor functioning thyroid tissue at before and (or) after^131I treatment.
Keywords:Cerenkov luminescence imaging  Iodine radioisotopes  Thyroid gland  Mice  nude  Radionuclide imaging
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号