首页 | 本学科首页   官方微博 | 高级检索  
检索        

387例艾滋病患者不规则抗体导致两种配血方法结果不合的分析
引用本文:孔亚红,王朔桂,秦盛峰,牟敏红.387例艾滋病患者不规则抗体导致两种配血方法结果不合的分析[J].国际输血及血液学杂志,2011,34(6):486-488.
作者姓名:孔亚红  王朔桂  秦盛峰  牟敏红
作者单位:1. 南宁市第四人民医院输血科, 南宁,530023
2. 南宁市红十字会医院检验科, 南宁,530012
基金项目:2010年广西壮族自治区卫生厅自筹经费科研课题项目
摘    要:目的 探讨艾滋病(AIDS)患者不规则抗体类型及性质,对两种交叉配血方法结果的影响.方法 选择2010年1月至12月在本院住院期间,需输血治疗的387例AIDS患者为研究对象.对其分别采用微柱凝胶法、凝聚胺法进行交叉配血及不规则抗体筛查实验(本研究遵循的程序符合本院人体试验委员会所制定的伦理学标准,得到该委员会批准,征...

关 键 词:艾滋病  凝聚胺法  微柱凝胶法  不规则抗体

387 Cases of AIDS Patients With Irregular Antibodies Lead to Incompatible Results Using Two Different Blood Analysis Methods
KONG Ya-hong,WANG Su-gui,QIN Sheng-feng,MU Min-hong.387 Cases of AIDS Patients With Irregular Antibodies Lead to Incompatible Results Using Two Different Blood Analysis Methods[J].International Journal of Blood Tranfusion and Hematology,2011,34(6):486-488.
Authors:KONG Ya-hong  WANG Su-gui  QIN Sheng-feng  MU Min-hong
Abstract:Objective To investigate the influence of the irregular antibody types and properties of AIDS patients to the results of two kinds of blood cross matching methods.Method From January to December 2010,387 cases of AIDS patients who received blood transfusion in Nanning Fourth People's Hospital were included in this study.Polybrene and micro-column gel methods were used in blood cross matching and irregular antibody screening test,respectively.The irregular antibody positive rate,blood cross matching mismatched rate,the sensitivity of these two kinds of matching methods,and irregular antibody types and properties were observed.The study protocol was approved by the Ethical Review Board of Investigation in Human Being of Nanning Fourth People′s Hospital.Informed consents were obtained from all participants.Results ① 182 cases with irregular antibodies were detected by micro column gel method with the non-consistent rate of 47.03 %(182/387).11 cases with irregular antibodies were detected by polybrene method with non-consistent rate of 2.84%(11/387).② The sensitivity was significant difference between two kinds of matching methods(x2 =9.6,P<0.005).③Irregular antibodies were low affinity,small molecular antibodies with the type of IgG+C3d+ IgA+,IgM,or anti-IgG,anti-C3d,antiIgA,and anti-IgM.Conclusion Because of the different types and properties of irregular antibody of AIDS patients,the results of two kinds of matching methods were not the same.
Keywords:AIDS  polybrene method  micro-column gel  irregular antibodies
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号