首页 | 本学科首页   官方微博 | 高级检索  
检索        

多指标联合检测鉴别渗出与漏出性胸腔积液的研究
引用本文:朱洪斌,孙耕耘.多指标联合检测鉴别渗出与漏出性胸腔积液的研究[J].国际呼吸杂志,2011,31(21):1621-1624.
作者姓名:朱洪斌  孙耕耘
作者单位:安徽医科大学附属第一医院呼吸内科,合肥,230022
摘    要:目的 检测胸腔积液患者胸腔积液胆固醇( PE CHOL)、胸腔积液胆固醇与血清胆固醇比值(P/S CHOL)、胸腔积液C-反应蛋白(PE CRP)和血清-胸腔积液白蛋白差(SEAG),并与Light标准进行比较,探讨多指标联合检测在鉴别渗、漏出性胸腔积液中的价值.方法 将137例不同病因的胸腔积液患者分成漏出液组和渗出...

关 键 词:渗出液  漏出液  胸腔积液  多指标  鉴别

Study on multiple-index joint inspection in diagnosis of exudative and transudatory pleural effusion
ZHU Hong-bin,SUN Geng-yun.Study on multiple-index joint inspection in diagnosis of exudative and transudatory pleural effusion[J].International Journal of Respiration,2011,31(21):1621-1624.
Authors:ZHU Hong-bin  SUN Geng-yun
Abstract:Objective To inspect pleural effusion cholesterol (PE CHOL),ratio of pleural effusion cholesterol and serum cholesterol (P/S CHOL),pleural effusion C-reactive protein (PE CRP) and serumeffusion albumin gradient (SEAG) to appraise the value of the multiple-index joint inspection in the diagnosis of the exudative and the transudatory pleural effusion.Methods 137 patients with different causes of pleural effusion were divided into transudate group and exudate group.Various indexes related to pleural effusion were inspected in parallel.ROC curve was obtained by analyzing the data of the statistics.Results The ratio of pleural effusion protein and serum protein,ratio of pleural effusion lactate dehydrogenase and serum lactate dehydrogenase,and pleural effusion lactate dehydrogenase in the exudative pleural effusion were higher than those in the transudatory pleural effusion (all P < 0.05).According to the Light standard,the sensitivity and specificity were 99% and 81%.PE CHOL,P/S CHOL,and PE CRP in the exudative pleural effusion were higher than those in the transudatory pleural effusion (all P <0.05).According to ROC curve,the determined diagnostic cutoff points were PE CHOL>1.52 mmol/L,P/S CHOL>0.32,and PE CRP>20 mg/L,the sensitivity were 93%,98%and 93%,the specificity were 89%,91% and 91%,respectively.SEAG in the exudative pleural effusion was lower than that in the transudatory pleural effusion (P <0.05).According to ROC curve,the determined diagnostic cutoff point was SEAG<10 g/L,the sensitivity and specificity were 81% and 91%,respectively.Conclusions The multiple-index joint inspection in the differential diagnosis is of great value.Compared with the Light standard,it has higher specificity.
Keywords:Exudate  Transudate  Pleutal effusion  Multiple indicator  Identification
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号