首页 | 本学科首页   官方微博 | 高级检索  
检索        


Myocardial area at risk and salvage measured by T2-weighted cardiovascular magnetic resonance: Reproducibility and comparison of two T2-weighted protocols
Authors:Jacob L?nborg  Niels Vejlstrup  Anders B Mathiasen  Carsten Thomsen  Jan S Jensen  Thomas Engstr?m
Institution:1.Department of Cardiology, Rigshospitalet, Copenhagen, Denmark;2.Department of Radiology, Rigshospitalet, Copenhagen, Denmark;3.Department of Cardiology, Gentofte Hospital, Copenhagen, Denmark
Abstract:

Background

Late Gadolinium Enhancement (LGE) and T2-weighted cardiovascular magnetic resonance (CMR) provides a means to measure myocardial area at risk (AAR) and salvage. Several T2-weighted CMR sequences are in use, but there is no consensus in terms of which sequence to be the preferred. Therefore, the aim of the present study was to: (1) Assess the reproducibility and (2) compare the two most frequently used T2-weighted CMR protocols for measuring AAR and salvage.

Methods

91 patients with ST-elevation myocardial infarction treated with primary percutaneous coronary intervention underwent a CMR scan 1-7 days after initial treatment. Two different T2-weighted protocols, varying in slice thickness and echo time (TE), were applied covering the entire left ventricle (LV) (protocol 1: TE 65 msec and slice thickness 15 mm; protocol 2: TE 100 msec and slice thickness of 8 mm). On a second scan performed 3 months later, infarct size was assessed with a standard LGE sequence. The two protocols were compared in terms of AAR and salvage index. Furthermore, intra- and interobserver reproducibility were assessed.

Results

Protocol 1 measures a larger AAR and salvage index than protocol 2 with a mean difference in AAR of 1 ± 8%LV (p < 0.01) and 6 ± 12 g (p < 0.01) and salvage index of 0.04 ± 0.12 (p < 0.01). Both protocols had a high intra- and interobserver reproducibility with acceptable limits of agreement (6-8%LV and 6-12 g in AAR and 0.06-0.08 in salvage index).

Conclusions

We report acceptable reproducibility for AAR and salvage index measured by T2-weighted images. Thus CMR is a reliable tool for measuring AAR and salvage index. Protocol 2 (8 mm slice thickness and 100 msec TE) measures slightly smaller AAR than protocol 1 (15 mm slice thickness and 65 msec TE), but the present study does not allow for a clear recommendation of either of the protocols.
Keywords:Cardiovascular magnetic resonance  area at risk  T2-weighted imaging  ST-segment elevation myocardial infarction  reproducibility
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号