生物样品组成对氯氮平浓度检测的影响
引用本文:马锦琦,周海梅,王琦玮,刘良,李朴.生物样品组成对氯氮平浓度检测的影响[J].中国医院药学杂志,2007,27(9):1250-1252.
作者姓名:马锦琦  周海梅  王琦玮  刘良  李朴
作者单位:1. 河南科技大学法医学院,河南,洛阳,471003
2. 华中科技大学同济医学院法医学系,湖北,武汉,430030
摘    要:目的:研究生物样品中盐、酯、蛋白质等成分的变化对固相微萃取-气相色谱质谱法检测氯氮平浓度的影响。方法:用固相微萃取-气相色谱质谱法测定样品中氯氮平(CLP)、洛沙平(内标),通过改变样品基质中氯化钠、醋酸乙酯、血浆的含量,观察盐、酯、蛋白质对CLP检测的影响。结果:随着样品中盐含量升高,CLP、洛沙平峰面积增大,方法灵敏度提高;随着样品中酯类、蛋白质含量升高,CLP、洛沙平峰面积减小,方法灵敏度降低。各组CLP、洛沙平峰面积保持相同的变化趋势,CLP与洛沙平峰面积的比值相对固定。结论:样品中盐、酯、蛋白质等含量的变化对固相微萃取-气相色谱质谱法检测氯氮平的灵敏度有不同程度的影响,但在选取合适内标的情况下并不影响定量分析的准确性。

关 键 词:生物样品成分  固相微萃取  气相色谱质谱  氯氮平  定量分析
文章编号:1001-5213(2007)09-1250-03
修稿时间:2006-05-29

The influence of biological specimen ingredient on determination of clozapine concentration in biological specimens
MA Jin-qi,ZHOU Hai-mei,WANG Qi-wei,LIU Liang,LI Pu.The influence of biological specimen ingredient on determination of clozapine concentration in biological specimens[J].Chinese Journal of Hospital Pharmacy,2007,27(9):1250-1252.
Authors:MA Jin-qi  ZHOU Hai-mei  WANG Qi-wei  LIU Liang  LI Pu
Institution:1. Department of Forensic Medicine , Henan University of Sicence and Technology, Henan Luoyang 471003, China; 2. Faculty of Forensic Medicine, Tongji Medical college, Huazhong University of Science and Technology, Huhei Wuhan 430030,China
Abstract:OBJECTIVE To study the influence of salt,ester,proteins in biological specimens on determination of clozapine concentration by Solid-phase microextraction-Gas Chromatography Mass Spectrometry(SPME-GC-MS).METHODS Clozapine and loxapine(internal standard)in these samples were detected by SPME-GC-MS,and the influence of solt,ester,proteins were observed by content variety of NaCl,ethyl acetate and plasma.RESULTS With the increased of content of salt in sample,peak areas of clozapine and loxapine increased and method sensitivity raised.With the increased of content of ester or proteins in sample,peak areas of clozapine and loxapine decreased and method sensitivity lowered.The peak areas of clozapine and loxapine had the same change tendency and peak area ratios of them remained almost constant in each group.CONCLUSION The changes of contents of salt,ester,proteins in samples will influence sensitivity of detection of clozapine by SPME-GC-MS,but the accuracy of quantitative analysis will not be influenced if suitable internal standard used.
Keywords:biological specimen ingredient  SPME  GC-MS  CLP  quantitative analysis  