首页 | 本学科首页   官方微博 | 高级检索  
检索        

Vitek1、Vitek2和BD Phoenix系统对超广谱β-内酰胺酶的检测和评价
引用本文:肖于飞,张嵘,徐志江,周宏伟,陈功祥.Vitek1、Vitek2和BD Phoenix系统对超广谱β-内酰胺酶的检测和评价[J].临床检验杂志,2006,24(4):250-252.
作者姓名:肖于飞  张嵘  徐志江  周宏伟  陈功祥
作者单位:浙江大学医学院附属第二医院检验科,杭州,310009;浙江大学医学院附属第二医院检验科,杭州,310009;浙江大学医学院附属第二医院检验科,杭州,310009;浙江大学医学院附属第二医院检验科,杭州,310009;浙江大学医学院附属第二医院检验科,杭州,310009
摘    要:目的评价Vitek1、Vitek2和BDPhoenix3台微生物鉴定和药敏系统对超广谱β-内酰胺酶(ESBLs)的检测。方法收集浙江大学医学院附属第一和第二医院临床分离的67株产ESBLs大肠埃希菌和肺炎克雷伯菌,利用聚合酶链反应、克隆测序的方法明确其基因型,同时在3台自动微生物鉴定和药敏系统上进行检测和分析,并检测细菌的最低抑菌浓度(MIC)。结果67株细菌主要以产CTX-M型为主,CTX—M-14、CTX—M-22、CTX—M.24和CTX—M-54种最常见,用Vitek—AMS检出60株ESBLs(89、6%),Vitek2检出62株ESBLs(92、5%),BD Phoenix检出63株ESBLs(94.0%)。不能检测的7株菌基因型主要为SHV-12、CTX—M-14、CTX-M-22及SHV-28基因型。对其MIC的检测结果显示主要为对多种抗生素均高耐药,或者为在临界点附近。结论3台微生物鉴定和药敏系统对ESBLs的检出率均高于89%,但是对高耐药菌株或者混合有其他酶的菌株的检测有待进一步研究和改进。

关 键 词:超广谱β-内酰胺酶  自动微生物鉴定和药敏系统  基因型
文章编号:1001-764X(2006)04-0250-03
收稿时间:2005-10-24
修稿时间:2006-03-15

Evalution of Vitek 1,Vitek 2 and BD Phoenix system for detection of extended-spectrum beta-lactamases
ZHANG Rong,XU Zhijiang,ZHOU Hongwei,CHEN Gongxiang.Evalution of Vitek 1,Vitek 2 and BD Phoenix system for detection of extended-spectrum beta-lactamases[J].Chinese Journal of Clinical Laboratory Science,2006,24(4):250-252.
Authors:ZHANG Rong  XU Zhijiang  ZHOU Hongwei  CHEN Gongxiang
Abstract:Objective To compare the application of three automated microbiology identification and rapid susceptibility assessment systems,Vitek1,Viket2 and BD Phoenix,in detection of extended-spectrum beta-lactamases(ESBLs).Methods The genotypes of 67 clinical isolates of ESBLs-producing E.coli and K.phneumoniae,which were collected from the 1st and 2nd Affiliated Hospital of Zhejiang University,were determined by PCR amplification and sequencing.Meanwhile,these isolates were analyzed by the three automatic microbiology identification system,and the minimum inhibitory concentration(MIC)s for antibiotics were determined.Results Majority of the 67 isolates produced CTXM type of ESBL.Among them,CTX-M-14,CTX-M-22,CTX-M24 and CTX-M-3 were the most frequently detectable types.By using Vitek-AMS,60 isolates(89.6%)were detected to be ESBLs-producing.By using Vitek2,62 isolates(92.5%) were ESBLsproducing.No SHV-12,CTX-M-14 and SHV-28 were detected by the 3 automatic systems.The results of MICs analysis indicated these isolates showed either high resistance for multiple antibiotics or around the boundary areas of MICs test.Conclusions The three automatic analysis systems are able to provide a detectable rate of more than 98% for ESBLs.However,it is needed to further improve the detection for high resistant strain or the strains carrying multiple resistant genes.
Keywords:
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《临床检验杂志》浏览原始摘要信息
点击此处可从《临床检验杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号