Diagnosis of deep vein thrombosis using multi-detector helical CT |
| |
Authors: | Kimura Masashi Minamiguchi Hiroki Sahara Shinya Yamada Katsuyuki Nakai Motoki Tanihata Hirohiko Kishi Kazushi Terada Masaki Shioyama Yasukazu Sato Morio |
| |
Affiliation: | Department of Radiology, Wakayama Medical University. |
| |
Abstract: | PURPOSE: To evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). Materials and Methods: The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. RESULTS: Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5 +/- 7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. CONCLUSION: MDHCT for the diangosis of DVT has the advantages of wider scanning range, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|