首页 | 本学科首页   官方微博 | 高级检索  
     


Synthetic MRI with T2-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain
Authors:Tokunori Kimura  Kousuke Yamashita  Kouta Fukatsu
Affiliation:Department of Radiological Science, Shizuoka College of Medicalcare Science, Hamamatsu, Shizuoka, Japan
Abstract:Purpose:Our purpose was to assess our proposed new synthetic MRI (synMRI) technique, combined with T2-based water suppression (T2wsup), to reduce cerebral spinal fluid (CSF)–partial volume effects (PVEs). These PVEs are problematic in the T2-weighted fluid-attenuation inversion recovery (FLAIR) images obtained by conventional synMRI techniques.Methods:Our T2wsup was achieved by subtracting additionally acquired long TE spin echo (SE) images of water signals dominant from the originally acquired images after T2 decay correction and a masking on the long TE image using the water volume (Vw) map to preserve tissue SNR, followed by quantitative mapping and then calculation of the synthetic images. A simulation study based on a two-compartment model including tissue and water in a voxel and a volunteer MR study were performed to assess our proposed method. Parameters of long TE and a threshold value in the masking were assessed and optimized experimentally. Quantitative parameter maps of standard and with T2wsup were generated, then wsup-synthetic FLAIR and SE images were calculated using those suitable combinations and compared.Results:Our simulation clarified that the CSF–PVE artifacts in the standard synthetic FLAIR increase T2 as the water volume increases in a voxel, and the volunteer MR brain study demonstrated that the hyperintense artifacts on synthetic images were reduced to < 10% of Vw in those with the standard synMRI while keeping the tissue SNR by selecting optimal masking parameters on additional long TE images of TE = 300 ms. In addition, the wsup-synthetic SE provided better gray-white matter contrasts compared with the wsup-synthetic FLAIR while keeping CSF suppression.Conclusion:Our proposed T2wsup-synMRI technique makes it easy to reduce the CSF–PVE artifacts problematic in the synthetic FLAIR images using the current synMRI technique by adding long TE images and simple processing. Although further optimizations in data acquisition and processing techniques are required before actual clinical use, we expect our technique to become clinically useful.
Keywords:synthetic magnetic resonance imaging   fluid-attenuation inversion recovery   partial volume effects   hyperintense artifacts   signal-to-noise ratio
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号