Endovascular aortic arch repair with a pre-cannulated double-fenestrated physician-modified stent graft: a benchtop experiment
Authors:Youcef Lounes  Lucien Chassin-Trubert  Thomas Gandet  Baris Ata Ozdemir  Antoine Peyron  Mariama Akodad  Pierre Alric  Ludovic Canaud
Institution:1.Department of Vascular and Thoracic Surgery, Arnaud de Villeneuve Hospital, Montpellier, France;2.Arnaud de Villeneuve Hospital, INSERM U1046, UM1, CHRU of Montpellier, Montpellier, France;3.Department of Cardio-Vascular Surgery, Arnaud de Villeneuve Hospital, Montpellier, France;4.Arnaud de Villeneuve Hospital, University of Bristol, Bristol, UK;5.Legal Department, Lapeyronie Hospital, Montpellier, France;6.Cardiology Department, Montpellier University Hospital, Montpellier, France
Abstract:Open in a separate windowOBJECTIVESThe critical step in total endovascular aortic arch repair is to ensure alignment of fenestrations with, and thus maintenance of flow to, supra-aortic trunks. This experimental study evaluates the feasibility and accuracy of a double-fenestrated physician-modified endovascular graft single common large fenestration for the brachiocephalic trunk and left common carotid artery and a distal small fenestration for left subclavian artery (LSA) with a preloaded guidewire for the LSA] for total endovascular aortic arch repair.METHODSEight fresh human cadaveric thoracic aortas were harvested. Thoracic endografts with a physician-modified double fenestration were deployed for total endovascular aortic arch repair in a bench test model. A guidewire was preloaded through the distal fenestration for the LSA. All experiments were undertaken in a hybrid room under fluoroscopic guidance with subsequent angioscopy and open evaluation for assessment.RESULTSMean aortic diameter in zone 0 was 31.3 ± 3.33 mm. Mean duration for stent graft modification was 20.1 ± 5.8 min. Mean duration of the procedure was 24 ± 8.6 min. The Medtronic Valiant Captivia stent graft was used in 6 and the Cook Alpha Zenith thoracic stent graft in 2 cases. LSA catheterization was technically successful with supra-aortic trunk patency in 100% of cases.CONCLUSIONSThe use of a double-fenestrated stent graft with a preloaded guidewire appears to be a useful technical addition to facilitate easy and correct alignment of stent graft fenestrations with supra-aortic trunk origins.
Keywords:Aortic arch  Aorta  Physician modified stent grafts  Thoracic endovascular aortic repair  Experimental
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号