Institution:1. Department of Cardiothoracic Transplantation and Mechanical Circulatory Support, Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, London, UK;2. Department of Cardiology, Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, London, UK;3. Cardiovascular Sciences, National Heart and Lung Institute, Imperial College London, London, UK
Abstract:Open in a separate window OBJECTIVESLeft ventricular assist device (LVAD) implantation for end-stage heart failure patients has been on the rise, providing a reliable long-term option. For some LVAD patients, longer term LV unloading leads to recovery; hence, the need for evaluating potential myocardial recovery and weaning eligibility has emerged.METHODSAll patients who underwent contemporary LVAD explantation at our institution between 2009 and 2020 were included in the study. Patients in New York Heart Association I, left ventricular ejection fraction >40%, a cardiac index >2.4 l/min and a peak oxygen intake >50% predicted underwent a 4-phase weaning assessment. A minimally invasive approach using a titanium plug was the surgery of choice in the most recent explants. Kaplan–Meier curves were used to estimate the survival at 1 and 5 years.RESULTSTwenty-six patients (17 HeartMate II, 9 HeartWare) underwent LVAD explantation after a median 317 days of support IQ (212–518)], range 131–1437. Mean age at explant was 35.8 ± 12.7 years and 85% were males. Idiopathic dilated cardiomyopathy was the underlying diagnosis in 70% of cases. Thirteen (48%) patients were on short-term mechanical circulatory support and 60% required intensive care unit admission prior to the LVAD implantation. At 1 year, Kaplan–Meier estimated survival was 88%, whereas at 6 years, it was 77%. The average left ventricular ejection fraction at 1 year post-explant was 44.25% ± 8.44.CONCLUSIONSThe use of a standardized weaning protocol (echocardiographic and invasive) and a minimally invasive LVAD explant technique minimizes periprocedural complications and leads to good long-term device-free survival rates.
Keywords:Left ventricular assist device  Myocardial recovery  Minimal invasive approach  Occlusion test  Left ventricular assist device explantation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号