首页 | 本学科首页   官方微博 | 高级检索  
     


Correlation of technetium-99m MIBI and thallium-201 retention in solitary cold thyroid nodules with postoperative histopathology
Authors:Tanju Yusuf Erdil  Kutlan Özker  Levent Kabasakal  Bedii Kanmaz  Kerim Sönmezoglu  Kayhan Çetin Atasoy  Halil Turgut Turoglu  Ilhami Uslu  Ali Tan Isitman  Çetin Önsel
Affiliation:(1) Department of Nuclear Medicine, Marmara University School of Medicine, Istanbul, Turkey, TR;(2) Department of Radiology, Medical College of Wisconsin, Milwaukee, Wis., USA, US;(3) Department of Nuclear Medicine, Cerrahpasa Medical Faculty, Istanbul University, Istanbul, Turkey, TR;(4) Department of Radiology, Ankara University School of Medicine, Ankara, Turkey, TR
Abstract:A comparative prospective study of technetium-99m methoxyisobutylisonitrile (MIBI) and thallium-201 with early (15 min) and delayed (90 min for MIBI, 3 h for 201Tl) imaging in the differentiation of thyroid lesions is presented. Forty patients with cold thyroid nodules visualised on 99mTc-pertechnetate scan and with dyskaryotic or atypical epithelial cells verified by fine-needle aspiration biopsy underwent MIBI and 201Tl scintigraphy at 3-day intervals. Subsequent thyroidectomies were carried out in all patients. Semiquantitative analysis was performed using a lesion to non-lesion ratio on early (ER) and delayed images (DR). Additionally, a retention index (RI) was calculated using the formula RI=(DR– ER) × 100/ER. The reproducibility of the method for the early and delayed measurements was tested by analysing intra- and inter-observer variability and repeatability coefficients. Histopathologically, the nodules were found to be well-differentiated thyroid cancer in 21 patients and benign in 19 patients. There was no significant difference in the ER between malignant and benign lesions for either 201Tl or MIBI (P>0.05). However, for both agents significant differences were found between malignant and benign lesions with regard to DR (P<0.01 for 201Tl and P<0.001 for MIBI) and RI (P<0.001 for both agents). Statistical comparison of the two agents showed no significant differences (P>0.05) except with regard to DR and RI in malignant nodules (P<0.05). A receiver operating characteristic analysis was performed to determine threshold levels for the differentiation of malignant from benign nodules. Following this analysis, ER, DR and RI levels of 1.03, 1.54 and 2 for MIBI and ≤1.42, 1.24 and 5 for 201Tl were selected. Using these threshold levels, the sensitivity, specificity and accuracy of the study were 90.5%, 36.8% and 65% for ER MIBI, 61.9%, 94.7% and 77.5% for DR MIBI, 95.2%, 89.4% and 92.5% for RI MIBI, 85.7%, 47.3% and 67.5% for ER 201Tl, 80.9%, 73.6% and 77.5% for DR 201Tl, and 90.5%, 94.7% and 92.5% for RI 201Tl. In conclusion, the DR for MIBI and 201Tl is superior to the ER in detecting malignant nodules, and the RI for both MIBI and 201Tl is more valuable than the DR in differentiating malignant from benign thyroid nodules. Received 24 October 1999 and in revised form 8 January 2000
Keywords:: Technetium-99m methoxyisobutylisonitrile  Thallium-201  Thyroid nodules
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号