首页 | 本学科首页   官方微博 | 高级检索  
检索        


Biocompatibility of Heparin-Coated Circuits in Pediatric Cardiopulmonary Bypass
Authors:Koji Kagisaki  Takafumi Masai  Keisi Kadoba  Yoshiki Sawa  Fumikazu Nomura  Norihide Fukushima  Hajime Ichikawa  Toshihiro Ohata  Ken Suzuki  Satoshi Taketani  Hikaru Matsuda
Institution:First Department of Surgery, Osaka University Medical School, Osoka, Japan
Abstract:Abstract: In this study, we evaluated the biocompatibility of heparin-coated circuits in pediatric cardiopulmonary bypass (CPB). Eight patients were divided into 2 groups: the control group (Group C) and heparin-coated group (Group H). In Group H, CPB circuits, including the arterial pump, oxygenator, and cannulas were heparin-coated. Before, during, and after CPB, blood samples were obtained to assess the platelet counts (Plat), α2-plasmin plas-minogen inhibitor complex (PIC), thrombin-antithrombin III complex (TAT), C3 activation products (C3a), inter-leukin (IL)-6, IL-8, and polymorphonuclear neutrophil leukocyte (PMN) elastase. There was no significant difference in Plat, PIC, or TAT between groups. Group H showed significantly low levels of C3a (during and after CPB), PMN elastase (during CPB), and IL-6 (after CPB). These data demonstrated that in pediatric CPB, heparin-coated CPB circuits reduced the activation of complements and the production of PMN elastase and IL-6, suggesting the superior biocompatibility of the heparin-coated circuits.
Keywords:Heparin-coated circuits  Biocompatibility  Pediatric cardiopulmonary bypass  complements  Elastase  Cytokines