Clearance of radioactive tantalum from the human lung after accidental inhalation.
Authors:D Newton
Abstract:Techniques of body radioactivity measurement were used to study the clearance of activated tantalum oxide accidentally inhaled by three reactor workers. The whole-body retention after 7 days was about 1% of the initial deposit. In one subject studied for a further 424 days the residual activity in the thorax was cleared with a biological half-life of about 1,400 days. The results support indications from other studies that tantalum powder administered in aerosol bronchography may be subject to prolonged alveolar retention.