首页 | 本学科首页   官方微博 | 高级检索  
检索        

危重冠心病围术期主动脉内球囊反博的临床应用分析
引用本文:张冬成,郭琳锐,林清文,俞晓立,曹嘉湘.危重冠心病围术期主动脉内球囊反博的临床应用分析[J].国际医药卫生导报,2010,16(15):1821-1823.
作者姓名:张冬成  郭琳锐  林清文  俞晓立  曹嘉湘
作者单位:广州医学院第二附属医院心外科,广州心血管疾病研究所,510260
摘    要:目的 回顾性总结危重冠心病围术期应用主动脉内球囊反博(1ABP)的经验,分析IABP置入的时机与临床治疗结果的关系,为提高IABP在危重冠心病患者的临床应用疗效提供依据.方法 1999年7月-2009年7月行冠状动脉搭桥术385例,其中21例病人围术期应用IABP辅助.将21例分为预防性主动置入组(主动组)8例和紧急被动置入组(被动组)13例.观察两组病人IABP使用的临床效果,包括围术期死亡率、IABP置入相关的严重并发症、平均辅助时间、血压改善情况、呼吸机辅助时间、ICU治疗时间等临床指标.结果 本组IABP应用占同期冠心病外科手术病人的5.5%.21例病人中,存活15例,死亡6例,总有效率71%,主动组术后死亡率明显低于被动组(P<0.01).两组的血压上升幅度、呼吸机辅助时间和ICU治疗时间差异有显著性(P<0.05),但两组的术后并发症发生率、IABP辅助时间差异无显著性(P>0.05).结论 对于术前评估为危重冠心病患者,术前预防性主动置入IABP能明显改善心功能,降低术后死亡率,缩短呼吸机辅助时间和ICU治疗时间,充分发挥IABP临床疗效.

关 键 词:冠状动脉搭桥术  主动脉内球囊反博术  疗效

Clinical analysis of perioperative application of intra-aortic balloon pump in high-risk coronary artery bypass grafting
ZHANG Dong-cheng,GUO Ling-lei,LIN Qin-wen,YU Xiao-li,CAO Jia-xiang.Clinical analysis of perioperative application of intra-aortic balloon pump in high-risk coronary artery bypass grafting[J].International Medicine & Health Guidance News,2010,16(15):1821-1823.
Authors:ZHANG Dong-cheng  GUO Ling-lei  LIN Qin-wen  YU Xiao-li  CAO Jia-xiang
Institution:. (Department of Cardiovascular Surgery, Guangzhou Institute of Cardiovascular Diseases, Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China)
Abstract:Objective To review the perioperative application of intra-aortic balloon pump (IABP) in high-risk coronary artery bypass grafting (CABG), and to analyze the relation between inserting time and clinical outcomes.Methods From July 1999 to July 2009, 385 patients underwent CABG and 21 of them were supported with IABP in our hospital. 21 were divided into two groups : group A (8 cases) supported preoperatively, and group B (13 cases) supported urgently. Postoperative mortality, severe IABP-related complications, supporting time, improvement of blood pressure, ventilation time, and length of ICU stay were compared. Results Of the patients undergoing CABG, IABP was 5.5%. 15 of all the patients survived. The rate of efficacy was 71%. Mortality was lower in group A than in group B (12.5%±2.1% vs. 38.5%±4.3%,P<0.01). There were significant differences between the two groups in improvement of blood pressure (35.4 ± 4.6 in group A vs. 18.2 ± 3.0 in group B, P
Keywords:Intra-aortic balloon pump  Coronary artery bypass grafting  Outcome
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号