首页 | 本学科首页   官方微博 | 高级检索  
检索        

有晶状体眼后房型人工晶状体拱高相关因素分析
引用本文:杜改萍,黄一飞,余继峰,宫玉波,宋静,赵海鹏,葛梅.有晶状体眼后房型人工晶状体拱高相关因素分析[J].中国实用眼科杂志,2011,29(1).
作者姓名:杜改萍  黄一飞  余继峰  宫玉波  宋静  赵海鹏  葛梅
作者单位:1. 100036,中国人民解放军总医院眼科;中国人民解放军401医院眼科
2. 中国人民解放军总医院眼科,100036
摘    要:目的 研究分析有晶状体眼后房型人工晶状体(implantable contactlens,ICL)拱高的相关性栽因素.方法 回顾性分析42例(77只眼)已行ICL矫正近视手术患者,屈光度-5.0~-23.0DS,在手术后6个月应用Oculus公司PentacamHR三维眼前节分析诊断系统进行ICL与透明晶状体的间隙即拱高(vault)的检查,并对vault进行相关性分析,统计方法 采用逐步回归的方法 进行多元分析.结果 术后6个月vault平均(452±216.38)μm.vault的多元回归分析相关性依次为ICL长度(回归系数B=0.040,P=0.000),白到白距离(B=-0.231,P=0.011),前房深度(B=0.138,P=0.048).结论 白到白距离较大和前房较深的病人,相对选择的ICL长度较大,得到的vault也较大,ICL与晶状体接触的机会就会降低.
Abstract:
Objective To evaluate the factor affecting vault after implantable collamer lens (ICL) implantation. Methods Retrospective research. All 77 eyes of 42 patients with myopic refractive errors of-5.00 to -23.00 dioptors undergoing ICL implantation were examined. The magnitude of the central vault of the ICL was assessed quantitatively using pentacam HR at 6 months after surgery. Multiple regression analysis was used to assess the factors affecting the amount of vault. Results The mean central vault at 6 months after surgery was 452± 216.38?m. Explanatory variables relevant to the vault were, in order of influence, the ICL length (regression coefficient B =0.040, P =0.000), the horizontal white to white distance (B =0.231, P =0.011) and anterior chamber depth, ACD (B =0.138, P=0.048). Conclusions A high white to white distances and ACD result long ICL, which is likely to render a high vault.

关 键 词:近视  人工晶状体  拱高  角膜  前房深度

Factors affecting vault after implantable contact lens implantation
DU Gai-ping,HUANG Yi-fei,YU Ji-feng,GONG Yu-bo,SONG-Jing,ZHAO Hai-peng,GE-Mei.Factors affecting vault after implantable contact lens implantation[J].Chinese Journal of Practical Ophthalmology,2011,29(1).
Authors:DU Gai-ping  HUANG Yi-fei  YU Ji-feng  GONG Yu-bo  SONG-Jing  ZHAO Hai-peng  GE-Mei
Abstract:Objective To evaluate the factor affecting vault after implantable collamer lens (ICL) implantation. Methods Retrospective research. All 77 eyes of 42 patients with myopic refractive errors of-5.00 to -23.00 dioptors undergoing ICL implantation were examined. The magnitude of the central vault of the ICL was assessed quantitatively using pentacam HR at 6 months after surgery. Multiple regression analysis was used to assess the factors affecting the amount of vault. Results The mean central vault at 6 months after surgery was 452± 216.38?m. Explanatory variables relevant to the vault were, in order of influence, the ICL length (regression coefficient B =0.040, P =0.000), the horizontal white to white distance (B =0.231, P =0.011) and anterior chamber depth, ACD (B =0.138, P=0.048). Conclusions A high white to white distances and ACD result long ICL, which is likely to render a high vault.
Keywords:Myopia  Phakic  Artificial lens  Vault  Corneal  Anterior chamber depth
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号