Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic posterior fixed partial dentures. Part II: Time efficiency of CAD-CAM versus conventional laboratory procedures |
| |
Authors: | Sven Mühlemann Goran I. Benic Vincent Fehmer Christoph H.F. Hämmerle Irena Sailer |
| |
Affiliation: | 1. Senior Teaching and Research Assistant, Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland;2. Senior Teaching and Research Assistant, Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland;3. Master Dental Technician, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland;4. Professor, Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland;5. Professor, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland |
| |
Abstract: | Statement of problemClinical trials are needed to evaluate the digital and conventional fabrication technology for providing fixed partial dentures (FPDs).PurposeThe purpose of the second part of this clinical study was to compare the laboratory production time for tooth-supported, 3-unit FPDs by means of computer-aided design and computer-aided manufacturing (CAD-CAM) systems and a conventional workflow. In addition, the quality of the 3-unit framework of each treatment group was evaluated clinically.Material and methodsFor each of 10 participants, a 3-unit FPD was fabricated. Zirconia was used as the framework material in the CAD-CAM systems and included Lava C.O.S. CAD software (3M) and centralized CAM (group L); CARES CAD software (Institut Straumann AG) and centralized CAM (group iT); and CEREC Connect CAD software (Dentsply Sirona) and centralized CAM (group C). The noble metal framework in the conventional workflow (group K) was fabricated by means of the traditional lost-wax technique. All frameworks were evaluated clinically before veneering. The time for the fabrication of the cast, the 3-unit framework, and the veneering process was recorded. In addition, chairside time during the clinical appointment for the evaluation of the framework was recorded. The paired Wilcoxon test together with appropriate Bonferroni correction was applied to detect differences among treatment groups (α=.05).ResultsThe total effective working time (mean ±standard deviation) for the dental technician was 220 ±29 minutes in group L, 217 ±23 minutes in group iT, 262 ±22 minutes in group C, and 370 ±34 minutes in group K. The dental technician spent significantly more time in the conventional workflow than in the digital workflow, independent of the CAD-CAM systems used (P<.001).ConclusionsIrrespective of the CAD-CAM system, the overall laboratory time for the dental technician was significantly less for a digital workflow than for the conventional workflow. |
| |
Keywords: | Corresponding author: Dr Sven Mühlemann Clinic of Fixed and Removable Prosthodontics and Dental Material Science Center of Dental Medicine University of Zurich Plattenstrasse 11 Zurich CH-8032 SWITZERLAND |
本文献已被 ScienceDirect 等数据库收录! |
|