首页 | 本学科首页   官方微博 | 高级检索  
检索        


Correlation between microtensile bond strength data and clinical outcome of Class V restorations
Authors:Siegward D Heintze  Chaiyasri ThunpithayakulSteven R Armstrong  V Rousson
Institution:a R&D, Ivoclar Vivadent, 9494 Schaan, Liechtenstein
b Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
c Department of Operative Dentistry, College of Dentistry, The University of Iowa, Iowa City, IA, USA
d Biostatistics Unit, Institute for Social and Preventive Medicine, University of Lausanne, Switzerland
Abstract:

Objective

To determine if the results of resin-dentin microtensile bond strength (μTBS) is correlated with the outcome parameters of clinical studies on non-retentive Class V restorations.

Methods

Resin-dentin μTBS data were obtained from one test center; the in vitro tests were all performed by the same operator. The μTBS testing was performed 8 h after bonding and after 6 months of storing the specimens in water. Pre-test failures (PTFs) of specimens were included in the analysis, attributing them a value of 1 MPa. Prospective clinical studies on cervical restorations (Class V) with an observation period of at least 18 months were searched in the literature. The clinical outcome variables were retention loss, marginal discoloration and marginal integrity. Furthermore, an index was formulated to be better able to compare the laboratory and clinical results. Estimates of adhesive effects in a linear mixed model were used to summarize the clinical performance of each adhesive between 12 and 36 months. Spearman correlations between these clinical performances and the μTBS values were calculated subsequently.

Results

Thirty-six clinical studies with 15 adhesive/restorative systems for which μTBS data were also available were included in the statistical analysis. In general 3-step and 2-step etch-and-rinse systems showed higher bond strength values than the 2-step/3-step self-etching systems, which, however, produced higher values than the 1-step self-etching and the resin modified glass ionomer systems. Prolonged water storage of specimens resulted in a significant decrease of the mean bond strength values in 5 adhesive systems (Wilcoxon, p < 0.05). There was a significant correlation between μTBS values both after 8 h and 6 months of storage and marginal discoloration (r = 0.54 and r = 0.67, respectively). However, the same correlation was not found between μTBS values and the retention rate, clinical index or marginal integrity.

Significance

As μTBS data of adhesive systems, especially after water storage for 6 months, showed a good correlation with marginal discoloration in short-term clinical Class V restorations, longitudinal clinical trials should explore whether early marginal staining is predictive for future retention loss in non-carious cervical restorations.
Keywords:Bond strength  Microtensile  Clinical  Class V  Correlation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号