首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of Hemodynamics in the Ascending Aorta Between Pulsatile and Continuous Flow Left Ventricular Assist Devices Using Computational Fluid Dynamics Based on Computed Tomography Images
Authors:Christof Karmonik  Sasan Partovi  Bastian Schmack  Alexander Weymann  Matthias Loebe  George P. Noon  Patrizia Piontek  Matthias Karck  Alan B. Lumsden  Arjang Ruhparwar
Affiliation:1. Department of Neurosurgery, The Methodist Hospital, , Houston, TX, USA;2. Methodist DeBakey Heart & Vascular Center, The Methodist Hospital, , Houston, TX, USA;3. Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, , Cleveland, OH, USA;4. Department of Cardiac Surgery, University Hospital of Heidelberg, , Heidelberg, Germany
Abstract:This study aims to investigate differences in hemodynamic conditions in the thoracic aorta for pulsatile and continuous‐flow left ventricular assist devices (LVADs) using computational fluid dynamics (CFD). Patient‐specific models were reconstructed from three patients with continuous‐flow LVAD (HeartMate II, Thoratec Corporation) and three patients with biventricular assist devices (Excor, Berlin Heart) where only the aortic part was included in the simulations. CFD simulations were performed with constant inflow for the continuous‐flow LVADs and time‐varying inflow for the pulsatile devices. Differences in flow patterns, wall shear stress (WSS), and dynamic pressure in the ascending aorta were compared for both cases. Retrograde flow patterns were observed in all cases proximal to the location of the outflow cannula anastomosis site. On average, dynamic pressures derived from the retrograde flow velocities were higher in the continuous‐flow group with large variations dependent on the angle of the cannula anastomosis relative to the ascending aorta (continuous group: 0.14 ± 0.2 mm Hg, pulsatile group: 0.013 ± 0.008 mm Hg). Elevated WSS contralaterally to the anastomosis site was observed in three of the six models with higher values for the continuous cases. Lower WSS and reduced pressure in the ascending aorta, both favorable hemodynamic conditions, were found in pulsatile versus continuous‐flow LVADs by means of CFD. These findings indicate, along with clinical observations reported by others, the superior performance of pulsatile LVADs.
Keywords:Hemodynamics  Left ventricular assist device  Pulsatile flow  Continuous flow  Computational fluid dynamics
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号