首页 | 本学科首页   官方微博 | 高级检索  
     

MALDI-TOF MS直接鉴定血培养阳性病原的临床应用
引用本文:侯伟伟,江涟,李冬. MALDI-TOF MS直接鉴定血培养阳性病原的临床应用[J]. 检验医学, 2021, 0(4): 424-429
作者姓名:侯伟伟  江涟  李冬
作者单位:同济大学附属同济医院检验科
摘    要:目的 了解基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)直接快速检测血培养报阳样本的可行性.方法 收集同济大学附属同济医院报阳血培养样本682例,从血培养瓶直接抽取血液至分离胶采血管离心富集细菌后,采用MALDI-TOF MS进行直接鉴定(快速质谱法).同时对报阳血培养标本进行涂片镜检及转种培养后,分别采...

关 键 词:基质辅助激光解吸电离飞行时间质谱  直接快速检测  血培养

Clinical application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in the direct detection of blood culture positive specimens
HOU Weiwei,JIANG Lian,LI Dong. Clinical application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in the direct detection of blood culture positive specimens[J]. Laboratory Medicine, 2021, 0(4): 424-429
Authors:HOU Weiwei  JIANG Lian  LI Dong
Affiliation:(Department of Clinical Laboratory,Tongji Hospital,Tongji University,Shanghai 200065,China)
Abstract:Objective To investigate the feasibility of matrix-assisted laser desorption ionization time-offlight mass spectrometry(MALDI-TOF MS)in the direct and rapid detection of blood culture positive specimens.Methods Totally,682 positive blood culture specimens were collected from Tongji Hospital.Blood was directly extracted from blood culture bottle and centrifuged in separated gel collecting tube.The centrifugally enriched bacteria were identified by MALDI-TOF MS.They were examined by slide review for the transmitted inoculation culture simultaneously.The culture colonies were identified by Vitek 2 Compact automatic microbial identification system and MALDI-TOF MS.The consistency of the identification results was compared.The strains with different results were verified by 16S rDNA gene sequencing.Results Among 682 blood culture positive specimens,664 cases were infected by single bacterium,and 539 strains(81.2%)were identified by MALDI-TOF MS,122 strains(18.4%)were not identified(species/genus),but only 3 strains(0.5%)were identified incorrectly(species/genus),including 1 case of Pantoea,1 case of Klebsiella pneumoniae and 1 case of Staphylococcus capitis.The 664 strains were infected by single bacterium,including 367 strains of Gram-negative bacteria,286 strains of Grampositive bacteria and 11 strains of Candidia albicans.Compared with the results of traditional colony identification,the accuracies(species/genus)of MALDI-TOF MS were 85.8%/6%,65%/3.1%and 63.6%/0%,respectively.The accuracy of Gram-negative bacteria was higher than those of Gram-positive bacteria and fungi(χ2=57.967,P<0.01;χ2=7.21,P<0.05).Among Gram-negative bacteria,the accuracies(species/genus)of Enterobacteriaceae,non-fermentative bacteria and other Gram-negative bacteria were 89.0%/5.0%,65.0%/10.0%and 66.7%/22.2%,respectively.Among Gram-positive bacteria,the accuracies(species/genus)of Staphylococcus,Enterococcus,Streptococcus and other Gram-positive bacteria were 70.9%/1.1%,71.4%/2.4%,40.5%/10.8%and 50%/7.1%,respectively.There were 18 cases of complex bacterium infection,of which the accuracy(species/genus)of one or two kinds of bacteria was 77.8%/0%.Conclusions It is feasible to apply MALDI-TOF MS in direct and rapid detection of positive blood samples,and the accuracy(species/genus)identified monotypic bacteria is high.The accuracy identified common clinical pathogenic bacteria was>70%.The results identified complex bacteria are not good.The rational identification ways should be chosen according to actual situation.
Keywords:Matrix-assisted laser desorption ionization time-of-flight mass spectrometry  Direct and rapid detection  Blood culture
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号