首页 | 本学科首页   官方微博 | 高级检索  
检索        

[牙合]垫对牙齿重度磨耗患者口颌功能影响的临床研究
引用本文:曹倩,于世宾,何惠明,王晓瑞.[牙合]垫对牙齿重度磨耗患者口颌功能影响的临床研究[J].临床口腔医学杂志,2012,28(1):39-42.
作者姓名:曹倩  于世宾  何惠明  王晓瑞
作者单位:第四军医大学口腔医院修复科 陕西西安710032
摘    要:目的:研究殆垫对牙齿重度磨耗患者口颌功能的影响。方法:用殆垫恢复10例牙齿重度磨耗患者的垂直距离,分别检测治疗前、治疗后1个月、3个月、6个月的咬合平衡性、咬肌及颞肌前束的肌电幅值、颌位及殆的稳定性以及边缘运动的平滑度及对称性的变化。结果:①咬合平衡性、颌位及胎的稳定性以及边缘运动轨迹的平滑度及对称性在治疗后呈逐渐改善趋势,治疗6个月后80%的患者恢复正常;②治疗后各组的息止位肌电幅值均较治疗前显著降低(P〈0.05),正中颌位紧咬时肌电幅值在治疗后3个月组和6个月组较治疗前显著增加(P〈O.05)。结论:通过6个月的治疗和观察,聆垫对重度磨耗患者的口颌功能的影响呈现持续改善趋势。

关 键 词:牙齿磨耗  耠垫  口颌功能  咬合重建

The clinical study on the effect of occlusal splint on stomatognathic function in patients with severe tooth wear.
CAO-Qian , YU Shi-bin , HE Hui-ming , WANG Xiao-rui.The clinical study on the effect of occlusal splint on stomatognathic function in patients with severe tooth wear.[J].Journal of Clinical Stomatology,2012,28(1):39-42.
Authors:CAO-Qian  YU Shi-bin  HE Hui-ming  WANG Xiao-rui
Institution:. Department of Prosthodotics , College of Stomatology, The Fourth Military Medical University, Shanxi Xian 710032, China
Abstract:Objective: To investigate the effect of occlusal splint on stomatognathic function in patients with severe tooth wear. Method:Occlusal splints were used to restore the occlusal vertical distance of 10 patients with severe tooth wear. The balance of occlusal force distribution, the EMG amplitude of the masseter and anterior temporal muscle, the sta- bility of mandibular position and occlusion, the smoothness and symmetry changes in maximal mandibular movement, were detected and analyzed before and 1,3,6 months after using occlusal splints. Result: ①The balance of occlusal force distri- bution, the stability of mandibular position and occlusion,the smoothness and symmetry changes in maximal mandibular movement, improved gradually after using occlussal splints. After 6 months treatment 80 % of patients recoverd to normal state. ②EMG amplitude of the masseter and anterior temporal muscle at rest position reduced significantly after treatment (P 〈0.05). EMG amplitude of the masseter and anterior temporal muscle at clenching intercuspal postion were higher signifi- cantly in 3 months and 6 months groups than pretreatment group (P 〈0.05). Conclution: Within the observational period of 6 months, occlusal splint can improve stomatognathic function of patients with severe tooth wear.
Keywords:tooth wear  occlusal splint  stomatognathic function
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号