首页 | 本学科首页   官方微博 | 高级检索  
检索        


Treatment of thoracolumbar fracture with pedicle screws at injury level: a biomechanical study based on three-dimensional finite element analysis
Authors:Qin-liang Li  Xiu-Zhong Li  Yi Liu  Hu-sheng Zhang  Peng Shang  Zhao-ming Chu  Jin-chuan Chen  Ming Chen  Rujie Qin
Institution:1. Department of Spinal Surgery, First People’s Hospital of Lianyungang Hospital Affiliated to Xuzhou Medical College, No. 182, Tongguan Road, Xinpu District, Lianyungang, 222000, Jiangsu Province, China
4. Traumatic Osteopathic of PLA Jinan Military General Hospital, Jinan, 250015, China
5. Hand Surgery of No. 401 Hospital of PLA, Qingdao, 266071, China
2. Institute of Mechanics, Chinese Academy of Sciences, Beijing City, 100190, Beijing, China
3. Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, Guandong Province, China
Abstract:The aim of this study was to investigate the biomechanical mechanisms of treatment of thoracolumbar compression fracture with pedicle screws at injury level based on a three-dimensional finite element method. We constructed one three-dimensional finite element model of T11-L1 in a patient with a compression fracture of the T12 vertebral body(anterior edges of vertebral body were compressed to 1/2, and kyphosis Cobb angle was 18.6°) fixed by four pedicle screws and another model fixed by six pedicle screws at the injured vertebrae, and then assigned different forces to the two models to account for axial compression, flexion, extension, left lateral bending, and rightward axial rotation by Ansys software. After different loading forces were applied to the models, we recorded stress measurements on the vertebral pedicle screws, as well as the maximum displacement of T11. The stress distribution suggested that stress concentration was appreciable at the root of the pedicle screws under different loading modalities. Under axial compression, flexion, extension, left lateral bending, and rightward axial rotation load, the stress for the superior screw was significantly greater than the stress for the inferior screw (P < 0.05). The stress in the six pedicle screw fixation model was significantly decreased compared to the four screw interbody fusion model (P < 0.05), but the maximum displacement of T11 between two models under different loadings was not statistically different. The use of pedicle screws at injured vertebral bodies may optimize internal fixation load and reduce the incidence of broken screws.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号